JD-2 Switches

You are installing one of the finest switches of its type on

the market. Design of this switch is based on the same

principles of sensitivity, accuracy, and dependability that

have made Antunes Controls Air Flow Switches so suc-

cessful. These switches are fully approved. They are

UL listed and recognized for the U.S. and Canada, and

approved by FM.

Dimensions

IMPORTANT

Please read these instructions carefully to assure

correct installation. This equipment must be

installed only by a licensed electrician who is

experienced with combustion safeguard control

systems and understands the functions of inter-

locking switches, such as gas pressure switches.

Prior to being put into operation in conjunction

with the combustion safeguard systems, all

switches should be tested for proper range setting

and proper wiring. Check piping connections and

switch house for leaks with a soap bubble test. All

exhaust fans and blowers should be inspected and

checked for proper rotation prior to starting up.

JD-2 Installation Information

Specifications

Blue Spring: .07” to 1.7” W.C. (2 mm to 43 mm)
Grey Spring: 0.1” to 4” W.C. (3 mm to 102 mm)
Purple Spring: 0.1” to 10” W.C. (3mm to 250 mm)
Red Spring: 0.1” to 24” W.C. (3 mm to 600 mm)
Orange Spring: 5” to 35” W.C. (125 mm to 875 mm)
Electrical: 10 A, 1/8 HP, 125 VAC; 5 A, 1/4 HP, 250 VAC;

Pilot Duty, 125 VA @ 125-250 VAC.
Field wiring by others must be rated at 194°F (90°C) for

industrial use.
Max. Operating Pressure: 35” W.C.
Max. Surge Pressure: 3 PSIG
Max. Ambient Operating Temperature: 140°F (60°C)
Min. Ambient Operating Temperature: -20°F (-28°C)
Shipping Weight: 1 lbs. (.45 kg)
Switches manufactured by Antunes Controls are tested,

listed, and approved by Underwriters Laboratories File #

MH8009-504, Factory Mutual Serial #18221, Canadian

Standards Association File #25144.

Range Adjustment

The JD-2 switch is adjustable within its range, as shown

on the range scale located on the top of the unit.

Mounting

The JD-2 is always mounted with the stem up. An

optional mounting bracket can be fastened to the bottom

section of the switch housing with a 5/16-18 x 1/2” bolt

(supplied with the bracket).

7/8”

(22 mm)

2 5/8”

(67 mm)

1/2”

(13 mm)

7/8”

(22 mm)

1 1/8”

(28 mm)

Large

Mounting

Holes:

5/16”

(8 mm) dia.

Small

Mounting

Holes:

7/32”

(5.5 mm) dia.

R

PRESSURE OR
VACUUM (AIR)

OPERATED

SWITCH

504H

LISTED

R

IN

W.C.

4

3

2

1

.5

.1

.81

3.75

1.59

.72

2.21

.89

4.06

1.88

2.32

.72

4.88

Ш.88

Ш.88

MODEL JD-2

FM

NEGATIVE INLET

POSITIVE INLET

1/8" NPT

1/8" NPT

SCREW CAP.

UNDER PROTECTIVE

ADJUSTING SCREW

5/16-18 NC

ON

OFF

GREY SPRING

MM
W.C.

102

W.C.

IN

4

75

50

13

25

3

3

2

.5

1

.1

ING

Note: Dimensions are for reference only.