Specifications

CONDITIONS

VOLTAGE DC (VDC)

CURRENT (Amp) OPERATING

TEMPERTURE

CABLE LENGTH

UL REFERENCE

NUMBER

Inputs

DC Input (NSC)

10.8 - 24VDC

0.03Amp

32° - 122°F
(0° - 50° C)

Input Circuits
500 ft (150 m)

= 22 AWG ● 0.65mm ● 0.33mm

2

18 AWG ● 1.02mm ● 0.82mm

2

Hi-O CAN Bus Total Length 100 ft (30 m) -

22 AWG ● 0.65mm ● 0.33mm

2

Maximum between drops 30 ft (10 m)

22 AWG ● 0.65mm ● 0.33mm

2

MEIMAxNN

X = K for Black

G for Gray

DC Input (MAX)

10.8 - 24VDC

0.04Amp

Supervised Inputs (MAX)

0 to 5VDC Reference

0.005 (Sink)

NSC = Normal Standby Condition
Note: The EdgeModule Input device senses changes in other devices.

Wiring

Input 1 Input 2

10

P3

1

Hi-O Group Select Jumper

Short = Group 1, Open = Group 2

Outside Door

Inside Door

( )

4

P1 1

* *

-

+

Input 3 Input 4

-

+

-

+

-

+

* Internal Optical Tamper Disable Jumper

CAN V+

GND

CAN H

CAN L

CANbus

Internal Optical Tamper

To disable the internal optical tamper sensor, attach a jumper wire from P3 pin 1 to P3 pin 2.

Note: If desiring an external tamper, wire an unsupervised Normally Closed contact, and replace the jumper.

EDGE EVO

®

Input Module

EIM-M

I

nstallatIon

G

uIde

82340-901, Rev B.1

October 2011

© 2011 HID Global Corporation. All rights reserved.

15370 Barranca Parkway
Irvine, CA 92618-2215
USA

Optional

Supervised Inputs

1-6K

N/O

1-6K

N/C

1-6K

1-6K

N/O

Designed for interfacing to general purpose inputs typically not associated with

standard access point control, the Input Module provides an interface to four input

analog/digital inputs. The module is always configured as general purpose input.