Another consideration is the processing that must occur after card data is read. The timing must be

adjusted to properly process data after the read operation. Recall from the Timing from Section

6.6.3 that the Card Present Line has a dual operational capability. When the OEM75 is configured

to be operating in Normal Power Mode, the Card Present Line is active high indicating that the

OEM75 PIC processor is functioning but no card is currently recognized. When a card is recognized

the Card Present Line goes active low for a configurable period of time called the Dealy TX period.

This is the time required by a host to prepare to receive Card data. When the Card Present Line

goes high again the OEM75 sends the Card Data to the Host. After the OEM 75 sends the card

data it enters a configurable period of time in which it listens for commands from the host. After this

period of time the OEM75 returns to waiting on the presentation of a card.