Mounting instructions, Connecting the reader to the host, Testing and operation – HID ProxPoint Plus Installation Guide User Manual

Page 2

Advertising
background image



_____________________________________________________________________________________________________
HID

Global 15370 Barranca Parkway, Irvine, CA 92618-1905 USA TEL: 949.732.2000 ● 800.237.7769 FAX: 949.732.2120

Web page

- www.hidglobal.com - ProxPoint Installation Manual 6005-910 Rev C.1

Page 2 of 2

PARTS LIST (Included)

Quantity

- ProxPoint™ Reader with snap-on
cover and 18” cable

1

- #4-24 x 1” self-tapping flathead screw

2

- Installation manual

1

PARTS LIST (Not-Included)

Quantity

- Wire splice

9

- DC Power supply 5.1 VDC or 12 VDC

1

Mounting Instructions

• Determine an appropriate mounting location. The reader

may be mounted to any surface, including metal.

• Drill two (2) 5/64-inch (2mm) holes approximately 1 inch

deep for mounting the reader.

• Drill a 5/8-inch (16mm) hole for the cable.
• Remove the snap-on cover from the reader and secure

the reader to the mounting surface.

• Route the cable from the reader and/or power supply to

the host. A linear type power supply is recommended.
Check all electrical codes for proper cable installation.

• Test the operation of the reader. After completion of the

test, replace the snap-on cover.

• For proper regulatory compliance, the drain wire should

be disconnected at the power supply end of the cable.

• Changes or modifications not expressly approved by the

party responsible for compliance could void the user’s
authority to operate the equipment.

• The Reader is intended to be powered from a limited

power source output of a previously certified power
supply.

In cold climates (-20

°F), when operating the Reader from

a 5V power supply, limit the cable distance to 200ft. For
longer cable distances, 12V is required.

Connecting the Reader to the Host


Connect the reader to the host according to the wiring
table below and the host installation guide.

Wiegand

Clock & Data

Wire Color

+DC +DC Red

Ground Ground Black

--- Card

Present

Violet

Data0 Data Green
Data1 Clock White

Shield Ground

Shield Ground

Drain

Green LED

Green LED

Orange

Red LED

Red LED

Brown

Beeper Beeper Yellow

Hold

Hold

Blue

Testing and Operation

• When power is applied to the reader the LED will

flash green three (3) times while the beeper beeps
simultaneously. The LED will then turn red. This
indicates that the microcontroller is operating
properly.

• Present an ID card to the reader. The LED will

momentarily turn green while the beeper beeps
once, indicating that the card was read
successfully.

Important Product Specifications


Power requirements (linear supply)
Operating Voltage Range 5.1 – 16.0 VDC
Peak Current 80 Ma
Average Current 5V or 12V 20 Ma
Maximum cable distance 500 ft (153 m)
To host
Maximum cable distance 200 ft (61 m)
To host @5V


FCC Compliance Statement: This device complies
with part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired operation.