DIP Switch Settings, continued

SW1-1, 2 and 3

Not used.

SW1-4 Keypad Operation.

The keyboard data can be processed by the reader or may be connected directly
to the Host. When Switch 1-4 is in the "off" position, the host is expected to
process any key presses (2 of 7 or 3 x 4 formats). When Switch 1-4 is in the "on"
position, the reader scans the keyboard and outputs the keyboard entries over the
selected interface. The message is the ASCII representation of the key that is
pressed. For example, if the “4” is pressed, the reader will output a <34 hex>
(ASCII encoded “4”).

SW1-5 Beeper Operation.

The Beeper may be enabled or disabled. If enabled, the reader will issue a beep
while flashing a green LED after a card is read. Switch 1-5 in the "on" position
enables the audible tone. Switch 1-5 in the "off" position disables the audible tone.

SW1-6 Terminating Resistor. Some RS422/RS485 connections require that the RX- line be terminated with a

resistor to RX+. If SW1-6 is in the "off" position, there is no terminating resistor on
RX-. If SW1-6 is in the "on", then a 120 ohm resistor is connected between RX+
and RX-.

SW1-7 Line Setting.

SW1-7 is used to configure the reader's interface configuration. SW1-7 should be
in the "off" position for RS232 and RS422 operation and “on” for RS485 operation.

SW1-8 Line Setting.

SW1-8 is used to configure the reader's interface configuration. SW1-8 should be
in the "off" position for RS232 and RS422 operation and “on” for RS485 operation.

SW2-1 Reader Interface.

SW2-1, SW2-2 and SW2-3 are used to select the reader's interface

SW2-2 Reader Interface.

configuration. Currently there are 3 options available. They are:

SW2-3 Reader Interface.

1. SW2-1 "on", SW2-2 "on" and SW2-3 "on" selects the RS232 interface.

2. SW2-1 "on", SW2-2 "on" and SW2-3 "off" selects the RS422 interface.

3. SW2-1 “on”, SW2-2 “off” and SW2-3 “off” selects the RS485 interface.

SW2-4, 5, 6, 7 and 8

Not used.

Product Configuration/Ordering Options

5352 A G N 00 -XXXX Y

Customer Custom Artwork or Firmware Number
1 through 9, A through Z


Customer Custom Number


Configuration Options - (00 standard)


Standard Hardware Options - N = None, K = Standard Keypad (internal or
2 of 7), S = Direct Connect Keypad (3 x 4 type)


Color - G = Gray, B = Beige


Current Revision Letter - may change without notice


Model Number 5352 = Serial ProxPro