Maintenance and care, Troubleshooting – Karcher NT 65-2 Ap EU User Manual

Page 15

Advertising
background image

– 4

ƽ

Danger

First pull out the plug from the mains before
carrying out any tasks on the machine.

Open filter door.

Replace the flat pleated filter.

Close the filter door, it must lock into
place.

Release and remove the suction head.

Clean the electrodes with a brush.

Insert and lock the suction head.

ƽ

Danger

First pull out the plug from the mains before
carrying out any tasks on the machine.

Check the receptacle and the fuse of
the power supply.

Check the power cable, the power plug
and electrodes of the device.

Turn on the appliance.

Empty the container.

Turn off the appliance and wait for 5 sec-
onds, turn it on again after 5 seconds.

Clean the electrodes as well as the
space between the electrodes with a
brush.

Remove blockages in the suction noz-
zle, suction tube, suction hose, or flat
pleated filter.

Exchange the paper filter bag.

Exchange the fleece filter bag (option).

Press the semi-automatic filter dedust-
ing key five times with the appliance
switched on.

Ensure the filter cover properly locks
into place.

Clean or replace the membrane filter
(special accessory) under running water.

Replace the flat pleated filter.

Check drain pipe for leaks.

Check for proper installation of the flat
pleated filter.

Replace the flat pleated filter.

Clean the electrodes as well as the
space between the electrodes with a
brush.

Continuously check the filling level in
case of non-conductive liquid.

Suction hose is not connected.

Inform Customer Service

Inform Customer Service

Maintenance and care

Exchanging the flat pleated filter

Cleaning the electrodes

Troubleshooting

Suction turbine does not run

Suction turbine turns off

Suction turbine does not start again

after the container has been

emptied

Suction capacity decreases

Dust comes out while vacuuming

Automatic shut-off (wet vacuum

cleaning) does not react

Semi-automatic filter dedusting

does not work

Semi-automatic filter dedusting

does not shut off

Semi-automatic filter dedusting

cannot be switched on