Change cartridge filter, Troubleshooting, Suction turbine does not run – Karcher NT 48-1 Te User Manual

Page 15: Suction capacity decreases, Dust comes out while vacuuming, Warranty, Accessories and spare parts, Special accessories, Warranty accessories and spare parts

Advertising
background image

– 4

Release and remove the suction head.

Turn the suction basket by 180° and
keep it aside.

Loosen the mounting nuts

Remove the cartridge filter.

Insert the new cartridge filter.

Insert the fastening nut and tighten it.

Insert and lock the suction head.

ƽ

Danger

First pull out the plug from the mains before
carrying out any tasks on the machine.

Check the receptacle and the fuse of
the power supply.

Check the power cable, mains plug and
socket of the appliance.

Turn on the appliance.

Float is blocking the suction canal.

Empty the dirt container.

Remove choking of suction nozzle, suc-
tion tube, suction hose, or cartridge filter.

Exchange the paper filter bag.

Clean or replace the membrane filter
(special accessory).

Change cartridge filter.

Check the proper installation of the car-
tridge filter.

Change cartridge filter.

The warranty terms published by the rele-
vant sales company are applicable in each
country. We will repair potential failures of
your appliance within the warranty period
free of charge, provided that such failure is
caused by faulty material or defects in man-
ufacturing. In the event of a warranty claim
please contact your dealer or the nearest
authorized Customer Service centre.
Please submit the proof of purchase.

Only use accessories and spare parts
which have been approved by the man-
ufacturer. The exclusive use of original
accessories and original spare parts
ensures that the appliance can be oper-
ated safely and trouble free.

At the end of the operating instructions
you will find a selected list of spare parts
that are often required.

For additional information about spare
parts, please go to the Service section
at www.kaercher.com.

Change cartridge filter

Troubleshooting

Suction turbine does not run

Vaccum turbine is running but the

machine is not sucking in dust/dirt

Suction capacity decreases

Dust comes out while vacuuming

Warranty