Troubleshooting – Karcher BP 1 Barrel Set User Manual

Page 19

Advertising
background image

– 7

Troubleshooting

Caution

To avoid risks, all repairs and replacement of spare parts may only

be carried out by authorized customer service personnel.

First pull out the plug from the mains before carrying out any tasks

on the machine.

Fault

Cause

Remedy

Pump runs but
does not trans-
port

Air in the pump

Plug in/ pull out the mains plug of
the pump a few times till the fluid
gets sucked

Suction area blocked

Pull out the mains plug and clean
the suction area

(only in manual mode) Wa-
ter level below the mini-
mum water level

Where possible, immerse the
pump deeper into the liquid or pro-
ceed according to the instructions
in the chapter describing the prep-
arations necessary for automatic
operation

Pressure hose is blocked

Pull out the mains plug and clean
the pressure hose

Locking tap is closed (ar-
row horizontal).

Open the locking tap (arrow vertical).

Pump does not
run or suddenly
comes to a
standstill during
operations

Power supply interrupted

Check fuses and electrical connections

Thermal protection switch
in the motor has switched
off the pump as it was over-
heated.

Pull out the mains plug, let the
pump cool down, clean the suction
area, prevent dry running

Dirt particles have got jammed
into the suction area

Pull out the mains plug and clean
the suction area

Pump operation stopped by
sensor

Check position of level sensor

Pumping ca-
pacity is reduc-
ing

Suction area blocked

Pull out the mains plug and clean
the suction area

Pumping ca-
pacity too low

The pumping capacity de-
pends on the flow height,
hose diameter and hose
length.

Keep max. flow height, see techni-
cal data. If necessary, select a dif-
ferent hose diameter or hose
length.

Our Kärcher branch will be pleased to help you further in the case of questions or
faults. See address on the reverse.

19