Transport storage maintenance and care – Karcher HD 1050 B User Manual

Page 17

Advertising
background image

– 6

For HD 1050 B:
Set the appliance switch at the engine
to OFF and close the fuel supply valve.

For HD 1050 DE:
Press the regulator lever at the engine
to "STOP" till the engine comes to a halt
and turn off the fuel tap.

Shut off water supply.

Activate hand spray gun until device is
pressure-less.

Secure the hand spray gun using the
safety catch so that it doesn't open ac-
cidentally.

Remove the water inlet hose from the
appliance.

Warning

Risk of damage! Freezing water in the ap-
pliance can destroy parts of the appliance.
Store the appliance in a heated room dur-
ing winter or empty it. During longer breaks
in operation, it is advisable to pump in anti-
frost agents into the appliance.

Screw off water supply hose and high
pressure hose.

Operate device for max. 1 minute until
the pump and conduits are empty.

Note: Observe handling instructions of the
anti-freeze agent manufacturer.

Pump in conventional frost protection
agents through the appliance.

A certain corrosion protection is achieved
with this as well.

Caution
Risk of injury and damage! Observe the
weight of the appliance when you transport
it.

Use the pushing handle to push the ap-
pliance.

When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.

Caution
Risk of injury and damage! Note the weight
of the appliance in case of storage.
This appliance must only be stored in inte-
rior rooms.

You can sign with your dealer a contract for
regular safety inspection or even sign a
maintenance contract. Please take advice
on this matter.
Note:The maintenance plan given below
only lists the maintenance tasks for the
high-pressure pump. The maintenance
tasks for the engine must also be done ac-
cording to the details given in the operating
instructions manual of the engine manufac-
turer.

Warning

Risk of injury if the machine is left running
in an unattended state. Remove the spark
plug before doing any work on the appli-
ance.
Risk of burns! Do not touch hot silencers,
cylinders or radiator ribs.

Check the high pressure hose for dam-
ages (risk of bursting). Please arrange
for the immediate exchange of a dam-
aged high-pressure hose.

Check oil level.

Please contact Customer Service immedi-
ately if the oil is milky (water in oil).

Clean the sieve in the water connection.

Clean filter at the detergent suck hose.

Frost protection

Drain water

Flush device with anti-freeze agent

Transport

Storage

Maintenance and care

Maintenance intervals

Daily

Weekly

Monthly

17

EN

Advertising