Troubleshooting

Fault

Possible cause

Remedy

of whom

Indicator lamp "Fault" glows
red

Filter full.

Clean or replace filter (see "Maintenance plan"). Operator

Dosing unit for splitting powder is
empty.

Switch off the plant. Fill up splitting powder up to
max. 2/3 of the dosing unit; restart the plant.

Operator

Dosing unit for liquid splitting agen
tis empty or dosing unit for sterilisa-
tion agent is empty (only for recy-
cling operations).

Switch off the plant. Top up liquid splitting agent
or sterilisation agent.

Operator

The short filling level probe in the
reaction tank gets triggered even if
the long probe in the reaction con-
tainer does not get triggered.

Switch off the plant. Empty the reaction tank,
clean the probes and then restart the plant. In-
form Customer Service if the short filling level
probe gets triggered again.

Operator

Contact problem in the reaction
tank (long filling level probe gets
triggered although the stirrer
shows "empty").

Switch off the plant. Clean the probes and then
restart the plant. Inform Customer Service if the
problem persists.

Operator

Contact problem in processed wa-
ter storage tank. Filling level probe
gets triggered although the long
probe shows "empty".

Switch off the plant. Clean the probes and then
restart the plant. Inform Customer Service if the
problem persists.

Operator

Contact problem of filling level
probes in the swimmer box of the
HDS - ASA/HDR attachment set
(possible only while recycling using
HDS - ASA/HDR attachment set).

Switch off the plant. Clean the probes and then
restart the plant. Inform Customer Service if the
problem persists.

Operator

Excess running of the pumps un-
der the reaction tank.

Inform Customer Service

Operator

Floater switch in the dirt collector
(option) is triggered.

Check plant and high-pressure cleaner and in-
form Customer Service if required.

Operator/Customer
Service

Stirrer shaft has got detached from
the motor shaft.

Faster the stirrer shaft back to the coupling; se-
cure the coupling.

Customer Service

Reaction tank overflows

Filling level probe in the reaction
tank is dirty, defective or adjusted
wrongly.

Check, clean, adjust or replace filling level
probes.

Operator/Customer
Service

Plant is not running

No supply voltage

Mains cable in socket? Check mains.

Operator

Dirt collector is empty.

Fill dirt collector or hang the dirt water pump a lit-
tle lower.

Operator

Processed water storage tank in
the filter unit is filled.

In recycling, wait till the processed water is con-
sumed by the high-pressure cleaner; otherwise
clean or replace the supply pump for high-pres-
sure cleaner.

Operator/Customer
Service

Contact problems or control is de-
fective.

Check contact or replace the control PCB.

Customer Service

Dirt water pump in the dirt
collector is not running

Pump is not connected, floater
switch S2 is not closed or pump is
defective.

Connect the pump. Connect the floater switch S2
or bridge the contact on the PCB. Clean or re-
place the pump.

Customer Service

Dirt water pump does not
switch off

Filling level probe in the reaction
tank is dirty or defective.

Clean or replace the filling level probe.

Customer Service

Strong foul odour

Dosing container for sterilisation
agent is empty.

Refill container.

Operator

Dosing in the dosing container for
the sterilisation agent is too less.

Increase dose.

Customer Service

Dosing solenoid valve is defective. Replace solenoid valve.

Customer Service

Sterilisation agent is no longer ac-
tive.

Check sterilisation agent and replace with a new
one, if required.

Operator/Customer
Service

Consumption of sterilisation
agent is very high

Dosing in the dosing container for
the sterilisation agent is too high.

Reduce dose.

Customer Service

Dosing solenoid valve is defective. Replace solenoid valve.

Customer Service

Processed water tank is
overflowing

Filling level probe in the processed
water tank is dirty or defective.

Clean or replace the filling level probe.

Operator/Customer
Service

Solenoid valve for fresh water sup-
ply is dirty or defective.

Clean or replace the solenoid valve.

Operator/Customer
Service

17