Transport storage maintenance and care – Karcher MIC 34C User Manual

Page 15

Advertising
background image

– 5

Note
Use normal glycol-based anti-freezing
agents for automobiles.
Observe handling instructions of the anti-
freeze agent manufacturer.
Î

Operate device for max. 1 minute until
the pump and conduits are empty.

1 Hose coupling
2 High-pressure cleaner
3 Safety pin

Î

Take the high pressure cleaner out of
operation.

Î

Disconnect the high pressure cleaner
hoses from the MC 50.

Î

Unlock the safety bolt by turning it and
pull it out toward the side.

Î

Pull the high pressure cleaner out of the
square pipes of the MC 50.

Î

Slide in the safety bolt and lock it by
turning it.

Caution
Risk of injury and damage! Observe the
weight of the appliance when you transport
it.
Î

When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.

Caution
Risk of injury and damage! Note the weight
of the appliance in case of storage.

ƽ

Danger

Risk of injury by inadverently starting appli-
ance. Switch the MC 50 off prior to working
on it and remove the ignition key.
Note
Please dispose off used oil only in the col-
lection points provided for them. Please
hand over old oil, if any, only at such plac-
es. Polluting the environment with used oil
is a punishable offence.

You can sign with your dealer a contract for
regular safety inspection or even sign a
maintenance contract. Please take advice
on this matter.

Î

Check all hydraulic hoses and connec-
tions and ensure that they are leak-
proof.

Î

Check the high pressure hose for dam-
ages (risk of bursting).
Please arrange for the immediate ex-
change of a damaged high-pressure
hose.

Î

Check appliance (pump) for leaks.
3 drops per minute are permitted and
can come out from the lower side of the
appliance. Call Customer Service if
there is heavy leakage.

Î

Check oil level Please contact Custom-
er Service immediately if the oil is milky
(water in oil).

Î

Clean the sieve in the water connection.
Unpressurize the appliance.
Unscrew lid with filter.

Disconnect the high pressure clean-

er from the MC 50.

Transport

Storage

Maintenance and care

Safety inspection/ maintenance

contract

Before each use

Weekly

15

EN

Advertising