Operation (Front Panel Pushbuttons)

Source Selection

To select a Source, press the pushbutton corresponding to the numbered Input.

The pushbutton will illuminate. A PC input will be routed to the PC output sockets.

A selected Video Input will also be routed to its respective Composite or S-Video

output.

If a PC input is selected, the last selected video input will remain on its respective

output and vice versa.

The Audio Channel will switch to the highlighted input, unless the unit is controlled by

RS232, in which case the Audio can be switched independently.

Note: The front panel displays the status of the PC / Video Inputs.

Blank / Mute

Press the Blank pushbutton to blank and mute the outputs.

The Blank button will illuminate and the Input buttons will extinguish.

The Sync of the last selected PC and Video Inputs (only) will be present on the

outputs.

Note: Blank and Mute are disabled when a source is selected.

Volume

The master volume control adjusts the level of all inputs (via the Up and Down
pushbuttons).

Note: The volume level for the selected audio input is permanently stored, even after switch
off.

Attenuation

The initial attenuation level of all the Inputs is set to 0dB. If some sources are louder than
others then they can be adjusted to match.

To change the attenuation level of an input, press and hold the Input Select

pushbutton, and press the Up and Down pushbuttons to set the level.

Release the pushbuttons to store the new attenuation level.

Display Device Serial Output

This can be used for direct control of any device with RS232 control (i.e: a projector).

The AVS-SL-PR-0401-0601 can be programmed to transmit Power On/Off as well as RGB,
Composite and S-Video mode commands to a display device using the Solecis Device
Configuration Software
application (downloadable from www.amx.com).

Dip switches 1-6 must be set to match the incoming source type on their

corresponding inputs.

The projector or display device should be switched to match the Source type output.

The commands are transmitted from the Display Serial terminal.

Input Mode Only

When the AVS-SL-PR-0401-0601 is powered up a mode command will be sent to a display
on the first press of any Input select button. The command will either be RGB, Composite or
S-Video depending on the button pressed. This will ensure a display device is set to the
correct mode to display the input selected. Each time a different source type is selected
then a mode command will be sent to the display device. For this function to work the
Display must be ON.

Power On/Off Mode

When the AVS-SL-PR-0401-0601 is powered up, a Power On command is sent to a display
on the first press of any input button.

Note: If the Power ON/OFF function is to be enabled, set a warm up/cool down time via the
Power On Timer and Power Off Timer settings, and click on Set / Enable - see
Controlling External Display Devices.

The button will flash for a programmed set time and the unit will disable. This allows a

projector to warm up.

At the end of the warm up period an RGB, Composite or S-Video command is sent to

the display, the AVS-SL-PR-0401-0601 enables and the system is ready for use.

To turn the controlled display (projector) off, press and hold the “Blank ON/OFF”

pushbutton (on the front panel) for 5 seconds.

Programming Cable Connections

Display Connections

RS232 Control

The unit may be controlled using an RS232 outputting system as follows.

Connections

Set the RS232 Protocol as follows: Baud Rate 9600, Data Bits 8, No Parity, Stop Bit 1.

The default address is 0.

Note: All commands are hexadecimal. For a complete listing of all supported GET and SET
commands, refer to the AVS-SL-PR-0401-0601 Operation/Reference Guide.

Solecis Device Configuration Software

This software (downloadable from www.amx.com) is used for configuring the
AVS-SL-PR-0401-0601 to control external display devices.

Connection

1.

Connect the serial port of the PC as follows:

2.

Launch the Solecis Device Configuration Software application. If the connection is
correct, the software will automatically detect the AVS-SL-PR-0401-0601.

3.

Click on the AVS-SL-PR-0401-0601to access the virtual panel (FIG. 2):

Operation

Inputs can be selected and their respective attenuation levels can be set.

The Master volume level can be adjusted and the front panel can be enabled/disabled.

If several units are to be externally controlled from one serial port, the address of each unit
can be changed.

Controlling External Display Devices

To program the AVS-SL-PR-0401-0601 to control external display devices:

1.

Click Setup Display. .

2.

Click Change and select the required Manufacturer, Display Type and Model. The
protocol and command strings will appear in the relevant fields.

If the required device is not in the library, then it can be added by selecting Library

from the menu bar and following the instructions.

Note: The device manufacturer's data sheet will be required.

If the string needs to be transmitted more than once, select the number of times from

the Count drop-down list and set a suitable interval period.

3.

If the Power ON/OFF function is to be enabled, set a warm up and cool down time via
the Power On Timer and Power Off Timer settings, and click on Set / Enable.

Note: If the warm up/cool down times are not enabled, Power ON/OFF will not work!

4.

Click on Program Device to download the information.

Additional Documentation

Refer to the Solecis AVS-SL-PR-0401-0601 Presentation Switcher Operation/Reference
Guide
(available online at www.amx.com) for details on installing and configuring the unit
as well as supported Commands and Troubleshooting info.

PC Serial Port (D9)

AVS-SL-PR-0401-0601

Pin 2

TX

Pin 3

RX

Pin 5

GND

Display device

AVS-SL-PR-0401-0601

RX

Display serial o/p

GND

GND

Controller

AVS-SL-PR-0401-0601

TX

RX

RX

TX (if feedback information required)

GND

GND

PC (D9)

AVS-SL-PR-0401-0601

Pin 2

TX

Pin 3

RX

Pin 5

GND

FIG. 2 Device Manager - Virtual Panel

FIG. 3 Device Manager - Setup Display

FIG. 4 Device Manager - Adding a Device to the Library

FIG. 5 Set warm up/cool down times via the Power On Timer and Power Off Timer settings