Advantech ADAM-4571 User Manual

Page 70

Advertising
background image

58 ADAM-4570/ADAM-4571/EDG-4504 User’s Manual

This chapter explains how to solve some of the most common
problems you could encounter while using ADAM-4570/
ADAM-4571/EDG-4504. If you are still having problems after
reading this chapter, contact your dealer, or e-mail Advantech
for help.

“Configuration Utility can not find ADAM-4570/ADAM-
4571/EDG-4504”

1. Check POWER LED. If it is off, you have to check :

• Make sure the ADAM-4570/ADAM-4571/EDG-4504
power cable is plugged in, and the server is receiving
power.

• Check that the server’s network connector is plugged in
properly.

• Make sure your computer is properly connected to the
network.

• The input voltage is between +10V and +30V

2. Check LINK LED. If it is off, you have to check:

• Network Connection is OK

• Make sure your network is 10/100 Mbps

3. If the above are completed, it means the ADAM-4570/

ADAM-4571/EDG-4504 is okay. Next, check to see if the
ADAM-4570/ADAM-4571/EDG-4504 and the host are on
the same local area network.

“Configuration utility can find ADAM-4570/ADAM-4571/
EDG-4504 but cannot access ADAM-4570/ADAM-4571/
EDG-4504”