Mount the light control, Wire the light control – Atlas Guardian Pro MLGC180W User Manual

Page 3

Advertising
background image

3

598-1098-02

Remove the existing light fixture.

Install the mounting strap as shown using two screws

that fit your junction box.

The plastic hanger can be used to hold the fixture

while wiring. The small end of the plastic hanger
can be threaded through the hole in the center of
the cover plate. The small end then goes into one
of the slots on the mounting strap.

Route the light control’s wires through the large
gasket holes.

Twist the junction box wires and fixture wires together

as shown. Secure with wire connectors.

White to
White

Black to
Black

Junction box ground wire to
green ground screw on fixture.

Gasket

Mounting

Strap

Mounting

Bolt

Rubber

Plug

Mount the Light Control

Align the light control cover plate and cover plate

gasket. Secure with the mounting bolt.

Align the three slots in the decorative shell with the

bulb holder pins. Push the shell in and then twist
clockwise to lock. Repeat for other shell.

Lock Nut

To avoid water damage and electrical shock,
keep bulb holders 30° below horizontal.

Adjust the bulb holders by loosening the lock nuts but
do not rotate the bulb holders more than 180° from
the factory setting. When screwing in the floodlamps,
do not overtighten.

Keep bulbs at least
1" (25 mm) from the
sensor. Do not allow
the bulbs to block
the lens.

Lens

Push the rubber plug firmly into place.

If a wet location junction box was not used, caulk

the wall plate mounting surface with silicone
weather sealant.

Shell Slot

Wire the Light Control

WARNING: Turn power off at circuit breaker

or fuse.

Advertising