SUMMARY

OPTIONS SELECTION

At the back of the thermostat, there are three selection switches to set at
your preferences.

Temperature in °C or °F, time in 12 or 24 hours and Early Start function.

TO SET TIME AND DAY

Press on DAY, HOUR and MIN buttons to adjust time and day.

TO RECORD THE

(COMFORT) SETPOINT TEMPERATURE

Select chosen setpoint temperature by using

or

button. Press on

button (2 to 3 seconds) until icon appears on display.

TO RECORD THE

(ECONOMY) SETPOINT TEMPERATURE

Select chosen setpoint temperature by using

or

button.

Press on

button (2 to 3 seconds) until icon appears on display .

CHECKING GROUND FAULT CIRCUIT INTERRUPTER (GFCI)

Adjust the setpoint temperature until heating indicator (

) appears on

display. Press on TEST button. The test is conclusive if the warning light
(GFI) on thermostat is ON and power to the load is cut-off (

remain

on display though). If these events do not occur, check the installation.
Press on RESET button to reset the GFCI.

OPERATING MODES

To select an operating mode, use MODE button.

AUTO:

Runs the program.

or

shows temperature setting

and can override temporarily your programming up to the
next program

MAN:

Maintains the selected temperature.

or

changes

the temperature setting.

Power-up

When power is applied for the first time, the
display must show the time 00:00, the floor
temperature and the manual mode icon (

).

Other information might show up on the display if
installation is defective or does not comply with
the instructions. The warning light (GFI) must be
off.

The message L0 or HI will appear on the display
if the temperature sensor is defective or the
temperature is below 0 °C (32 °F) or higher than
60 °C (140 °F). Also, the heating indicator will be
present on display and the relay will be closed
(current going in the load).

Checking ground fault circuit interrupter (GFCI)

Adjust the setpoint temperature until
heating indicator (

) appears on

display. Press on TEST button. The test is
conclusive if the warning light (GFI) on the
thermostat is ON and power to the load is
cut-off. If these events do not occur, check
the installation. Press on RESET button to
reset the GFCI.

If the GFCI test fails:
Check the load wires. The thermostat
must be in heating mode to carry out the
test (heating indicator ON).

The GFCI test should be carried out
monthly. If the test fails, cut off the electric
power to the heating system and

call

customer service or return the thermostat
to your supplier for verification. If the
warning light comes on during normal
operation, cut off power to the heating
system and have an electrician verify the
installation.

MODEL TH111GFCI-P (120 VAC)

INSTALLATION

This thermostat is designed to control floor electric heating systems. The
resistive load must not exceed 2000 watts (NI) @ 120 VAC (16.7 A). The
thermostat is equipped with a ground fault circuit interrupter (GFCI) and therefore
the isolation of the line and load are required for operation. The polarity of line
connection (line and neutral) must be respected. During a ground fault, only the
current in the black wire (line) of the load will be cut-off. Connect thermostat as
shown on diagram.

Electricians or experienced technicians should install the thermostat.

This thermostat is designed to be used with a circuit breaker.

PARTS INCLUDED

- One (1) TH111 GFCI-P (120 VAC) thermostat
- Two (2) 6-32 screws
- Four (4) solderless connectors (for copper wire)
- One (1) Temperature sensor with a 15 foot extension

TURN OFF POWER OF THE HEATING SYSTEM AT THE MAIN POWER
PANEL TO AVOID ELECTRICAL SHOCK.
Keep air vents of the thermostat
clean and free from obstructions.

1) Connecting wires and mounting thermostat

Connect the rear thermostat wires
to the power supply and to the
load using solderless connectors
for copper wires. See schematic
diagram.

u

u

u

u

u

u

Push the excess wire back into
the electrical box

to prevent

interference with the thermostat.
Secure the thermostat using two
(2) 6-32 screws . Once the ther-
mostat is properly installed, return
power to heating system.

NOTE : All cables and connec-
tions must conform to the local
electrical code.

WARNING : Special CO/ALR solderless connectors must be used when
connecting with aluminum conductors.

2) Connecting temperature sensor wire

Connect the temperature sensor
wire to the two lower screws of the
terminal block at the back of the
thermostat (no polarity need to be
respected). The wire must pass
outside the electrical box and fol-
low the wall down to the floor. The
sensing probe should be placed in
a representative heat area for
maximum system perfomance.
The sensing probe should be cen-
tered between the wires in the
mat. The temperature sensor wire
cannot cross any heater wires and
the sensing probe must not be
directly or adjacent to a heating
wire.

VAC

120

60 HZ

VAC

120

60 HZ

920-111-021-00-1-A

1/2

OPERATING MODES

The TH111GFCI-P has two (2) operating modes.

M

ANUAL

(

)

This mode allows you to maintain a constant temperature of the floor.

1- To activate this mode, press on Mode button to display the

icon.

2- Set the desired temperature using the

buttons or select the

pre-programmed

or

or

settings.

(To select the

setting, press on

and

simultaneously.)

AUTO

MATIC

(

)

This mode executes your own programming.

To activate this mode, press on Mode button to display the

icon.

The

or

icon indicates which temperature setting is used. Also, the icon

of the program number will be shown.