Remove HANDLE (2).

Remove two SCREWS (6) holding ESCUTCHEON (7)

and remvoe ESCUTCHEON (7).

Remove CAP (3), SCREWS (5) and CARTRIDGE (1).

Clean inlets and MANIFOLD (4).

Reassemble CARTRIDGE (1), alternately tightening SCREWS (5).

Replace CAP (3) and HANDLE (2). Check flow.

If faucet drips, operate handle several times
from "off" to "on". Do not apply excessive force.

Clogged CARTRIDGE (1) inlets may cause
reduced flow in "full on" hot or cold. To clean
inlets, first turn off water supply, then:

SERVICE



2

7

1

6

5

3

)

$

0''

4

Remove CARTRIDGE (1) by removing CARTRIDGE SCREWS (2). Remove three SCREWS (3) from
FIXATION RING (4) and pull out PRESSURE BALANCING (5) unit.

Clean SEALS (9) on base of CARTRIDGE (1). Check base of PRESSURE BALANCING UNIT (5) and clean O-RINGS (6).
Remove CAPS (7) and check O-RINGS on inside of CAPS (7). Clean inside sealing surfaces of VALVE BODY (8).

Re-assemble PRESSURE BALANCING UNIT (5) and CARTRIDGE (1). Tighten all screws.

Turn on water supply and see above for installing TRIM and HANDLE.

Remove handle and trim.

SERVICE: VALVE LEAKS WHEN SHUT OFF

BACK TO BACK INSTALLATION

Remove PRESSURE BALANCE UNIT (5).

Remove CAPS (7) and clean valve thoroughly.

Examine balancing unit and check condition of O-ring on end of piston. Piston should move back and forth.
Order Repair Part M952100-0070A if balancing unit is defective.

Replace CAPS (7) and install PRESSURE BALANCE UNIT (5). Make sure inlets line up with two holes in bottom
of casting. Top flange should butt-up against top of casting.

Remove PRESSURE BALANCE UNIT (5). Rotate PRESSURE BALANCE UNIT (5) 180˚ so that the inlets face up
and the large outlet port faces down.

Push PRESSURE BALANCE UNIT (5) in casting make sure inlets line up with holes in bottom of casting.
Top flange should butt up against top of casting.

Reassemble FIXATION RING (4) and CARTRIDGE (1).

UNABLE TO MAINTAIN CONSTANT TEMPERATURE

BACK TO BACK INSTALLATION

ROTATE 180˚

1

2

9

5

5

7

8

6

4

3

INLETS

LARGE OUTLET

EverClean™ Finish Care Instructions

American Standard’s EverClean finish will wipe clean with a soft, dry cloth. A soft cloth with
clean water may also be used, if desired. No additional cleaning products are required.

DO NOT USE: Soaps, acid, polish, abrasives, harsh cleaners, or a cloth with a coarse surface.

.      

Advertising