Installation, Dimensional clearances machine foundation, Caution – Alliance Laundry Systems CFD16C User Manual

Page 17

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

15

9001909

Installation

Dimensional Clearances

Table 1 shows recommended minimum clearances on
all sides of the washer-extractor.

Machine Foundation

Thoroughness of detail must be stressed with all
foundation work to ensure a stable unit installation,
eliminating possibilities of excessive vibration during
extract.

The washer-extractor must be placed on a smooth
level surface so that the entire base of the machine is
supported and rests on the mounting surface.

The standard installation does not require anchoring
unless mandated by state or local codes.

Kinetic energy of the cylinder and dynamic loads on
the floor or foundation are shown in Table 2.

Table 2 can be used as a reference when designing
floors and foundations.

Recommended Minimum Clearances

Model

18

30

33

40

Minimum rear
clearance

24 in.

(600 mm)

24 in.

(600 mm)

24 in.

(600 mm)

24 in.

(600 mm)

Minimum
clearance
between
machine and
wall

6 in.

(150 mm)

6 in.

(150 mm)

6 in.

(150 mm)

6 in.

(150 mm)

Minimum
clearance
between
machines
(side)

1 in.

(25.4

mm)

1 in.

(25.4

mm)

1.2 in.

(33 mm)

1.2 in.

(33 mm)

Minimum front
clearance (door
swing)

16.5 in.

(419 mm)

16.5 in.

(419 mm)

21 in.

(533 mm)

21 in.

(533 mm)

Table 1

Floor Load Data

Model

18

30

33

40

Kinetic
energy of
the
cylinder

1386 N/m 2592 N/m 2736 N/m 4105 N/m

Dynamic
bottom
load

700 N/16

Hz

1000 N/

16 Hz

1200 N/

16 Hz

1200 N/

16 Hz

Table 2

Ensure that the machine is installed on a
level floor of sufficient strength and that
the recommended clearances for
inspection and maintenance are provided.
Never allow the inspection and
maintenance space to be blocked.

W488

CAUTION

Advertising