ADCC0200 and ADCC0300

Multiple Keyboards on an RS485 Network

A maximum of 16 devices may be connected when working in RS485 mode. A maximum
of eight keyboards can be assigned to the system.

For correct connection of multiple keyboards to an MegaPower LT, please see the
MegaPower LT Installation and Operation Handbook.

Terminating/Biasing the RS485 Network

The keyboard has built in RS485 network termination and/or biasing. For most small to
medium sized installations, it should not be necessary to change the switches from their
default settings. Only for large installations should your network require biasing and/or
terminating. The switches are shown below for your reference. The default setting for
switches 1, 2 and 3 is OFF (UP). Switch 4 is not used.

*Default setting

Network setting

Switch 1

Switch 2

Biased

ON

ON

Not Biased*

OFF*

OFF*

Network setting

Switch 3

Terminated

ON

Not Terminated*

OFF*

*Default setting