Keyboard Installation and Operation

Multiple Keyboards on an RS232 Network

Use the following diagram as guidance to connect multiple RS232 keyboards via a port
expander. The following rules must be observed:

1.

A maximum of four RS232 keyboards can be connected to the network.

2.

The distance between two system components should not exceed 50 feet/15
meters.

3.

All cables are to be screened/shielded Cat 5 or better.

4.

Keyboards require a separate power supply via a MP-KMI.

Note
For correct connection of multiple keyboards to an MegaPower LT, please see the
MegaPower LT Installation and Operation Handbook.