(Effective System Protection):

maximum system output with

minimal pump starts

The ESP sizing procedure covers modern residential water-use habits, increased off-peak

demands and the general increase in water use that have occurred over the past twenty-five years.
ESP sizing is designed to reduce pump wear and tear, and reduce energy consumption by keeping

pump starts to a minimum.

Choose the amount of protection you need.

ESP I:

Tank selection is based on approximately one minute minimum pump running time.

This is recommended for pumps up to 3/4 H.P.

ESP II:

Tank selection is based on approximately two minute minimum pump running time.

This is recommended for 3/4 H.P. or larger pumps.

ESP Sizing Table

OPERATING PRESSURE - PSIG

PUMP DISCHARGE

ESP I

ESP II

RATE GPM (Approx.)

20/40

30/50

40/60

20/40

30/50

40/60

5

WX-202

WX-202

WX-202

WX-202XL

WX-205

WX-205

7

WX-202

WX-202

WX-202XL

WX-205

WX-250

WX-251

10

WX-202XL

WX-205

WX-205

WX-251

WX-251

WX-255

12

WX-205

WX-250

WX-250

WX-251

WX-255

WX-255

15

WX-250

WX-250

WX-251

WX-255

WX-302

WX-350

20

WX-251

WX-251

WX-255

WX-350

WX-350

(2) WX-255

25

WX-251

WX-255

WX-302

(2) WX-251

(2) WX-255

(2) WX-302

30

WX-255

WX-302

WX-350

(2) WX-255

(2) WX-302

(2) WX-350

35

WX-302

WX-350

WX-350

(2) WX-302

(2) WX-350

(2) WX-350

40

WX-350

WX-350

(2) WX-255

(2) WX-350

(2) WX-350

(3) WX-302