Chapter 7

35

Avaya P130 SMON User Guide

Tooltips

Tooltips in the Alarms and Events tool provide information about an

Alarm. When the cursor is held over the

Index

field of a row in the Alarms

Table a tooltip appears.

Figure 7-2. Alarm Tooltip

The tooltip provides information about the Alarm’s definition. In addition,

it shows the ‘raw’ number of packets (or octets) which will generate a

Rising or Falling Event. The raw number is the actual number of packets

(or octets) that must enter the port in order to generate an Event. This

number is equal to the defined rate times the interval.

For example, if an Alarm is defined for Broadcast packets with an Interval

of 15 seconds, a Rising Threshold of 1,000 packets per second and a

Falling Threshold of 100 packets per second, the raw number for a Rising

Event is 15,000 and for a Falling Event 1,500. If 15,000 or more Broadcast

packets enter the port in a 15 second interval, a Rising Event is generated.

The following table provides a list of the fields in Tooltip with their

descriptions.

Table 7-2. Tooltip Fields

Field

Description

Index

A number identifying the Alarm.

Port

The port or LAG for which the Alarm was configured.

Counter

The counter being monitored by the Alarm.

Last Value

The value of the counter calculated for the last interval.

Rising Threshold

[raw]

The Rising Threshold expressed as the number of packets

or octets in an interval.

Last Rising Time

The time of the last Rising Event.

Falling

Threshold [raw]

The Falling Threshold expressed as the number of packets

or octets in an interval.