Item Number

Data

Remarks

Item name

Upper byte

Lower byte

Item name

Upper byte

Lower byte

Status Error

01h

01h

No Error

00h

00h

Get

Lamp Error

00h

01h

Fan Error

00h

02h

Cover Error

00h

04h

Temp Error

00h

08h

Status Power

01h

02h

Stanby

00h

00h

Start Up Lamp

00h

02h

Power On

00h

03h

Cooling1

00h

04h

Cooling2

00h

05h

Saving Cooling1

00h

06h

Saving Cooling2

00h

07h

Saving Stanby

00h

08h

Lamp Timer

01h

13h

Lamp Use Time

0000h - FFFFh

ROM Version

01h

1Dh

MAIN ROM Version

0000h - FFFFh

Status Security

01h

1Fh

Disable

00h

00h

Enable

00h

01h

Sircs (15 Bit Category)

17h

_

00h

Sircs (20 Bit Category)

19h

Refer to table 4
Refer to table 5

_

00h

00h
00h

Set only

*4

*1

*2

*3

<Table 3>

Item Number

Data

IItem

Data

Upper byte

Lower byt

ACK

_

00h

00h

NAK

Select Error

01h

05h

When sending a command, wait for at least 50 ms after the reception of response.
No response may be returned when turning on the power.

*1 Example) In case the lamp timer indicates 1000H, return values are [03h] upper byte and [E8h] lowerbyte.
*2 Example) In case the software version is 1.03, return values are [01h] upper byte and [03h] lowerbyte.
*3 With the unit in which the security lock is set, whether the password input screen is displayed can be checked after the power turns on. When the password

input screen is being displayed, return values are [00h] upper byte and [01h] lower byte.

*4 It is corresponded to single command only.