American Standard SERIN T064.60X User Manual

Page 3

Advertising
background image

5

Unthread LEVER HANDLE, loosen SET SCREW and pull
HANDLE off valve stem.
To remove Escutcheon assembly reverse steps in Step 3.

TO GAIN ACCESS TO VALVE FOR SERVICING

Remove CARTRIDGE (1) by removing CARTRIDGE SCREWS (2).
Remove three SCREWS (3) from FIXATION RING (4) and pull
out PRESSURE BALANCING (5) unit.
Clean SEALS (9) on base of CARTRIDGE (1). Check base of
PRESSURE BALANCING UNIT (5) and clean O-RINGS (6). Remove
CAPS (7) and check O-RINGS on inside of CAPS (7). Clean inside
sealing surfaces of VALVE BODY (8).
Re-assemble PRESSURE BALANCING UNIT (5) and CARTRIDGE (1).
Tighten all screws.
Turn on water supply and see above for installing TRIM and HANDLE.

VALVE LEAKS WHEN SHUT OFF

BACK TO BACK INSTALLATION

ROTATE 180

˚

BACK TO BACK INSTALLATION
Remove PRESSURE BALANCE UNIT (5). Rotate PRESSURE BALANCE UNIT (5) 180˚ so that the inlets face up
and the large outlet port faces down.
Push PRESSURE BALANCE UNIT (5) in casting make sure inlets line up with holes in bottom of casting.
Top flange should butt up against top of casting.
Reassemble FIXATION RING (4) and CARTRIDGE (1).

Remove PRESSURE BALANCE UNIT (5). Remove CAPS (7)
and clean valve thoroughly.
Examine balancing unit and check condition of O-ring on end of
piston. Piston should move back and forth. Order Repair
Part M952100-0070A if balancing unit is defective.
Replace CAPS (7) and install PRESSURE BALANCE UNIT (5).
Make sure inlets line up with two holes in bottom of casting.
Top flange should butt-up against top of casting.

UNABLE TO MAINTAIN CONSTANT TEMPERATURE

1

2

9

5

5

7

8

6

4

3

INLETS

LARGE OUTLET

PIPE
PLUG

4

INSTALL HANDLE, DIVERTER KNOB, TUB
SPOUT AND SHOWER

5

6

Remove pipe cap and plug from shower and tub
rough piping.
Install SPOUT ESCUTCHEON (9) onto TUB SPOUT (10).
Apply sealant or Teflon tape to threads of tub filler
nipple. Thread TUB SPOUT (10) onto tub nipple.
Install SHOWER ESCUTCHEON (11) onto SHOWER
ARM (12). Apply sealant or Teflon tape to threads on
both ends of SHOWER ARM (12) and thread longer
leg of SHOWER ARM (12) into shower elbow.
Thread SHOWER HEAD (13) onto SHOWER ARM (12).

ADJUST HOT LIMIT STOP

By restricting HANDLE rotation and limiting the amount of hot
water allowed to mix with the cold, the HOT LIMIT SAFETY
STOP (1) reduces risk of accidental scalding. To set the maximum
hot water temperature of your faucet, all you need to do
is adjust the setting on the HOT LIMIT SAFETY STOP (1).

15

13

11

97

53

10

3

Turn CARTRIDGE STEM (2) to the OFF position (coldest setting)
before making adjustment to HOT LIMIT STOP (1). Use a flat
blade screwdriver to pry free the HOT LIMIT SAFETY STOP (1).
Pull forward and rotate counterclockwise one number to limit hot
water temperature. Use ARROW (3) on CARTRIDGE (4)
and NUMBERS (5) on HOT LIMIT STOP (1) for
indication.

1

5

4

3

2

15

1

3

1

1

9

7

5

3

1

1

5

1

3

1

1

9

7

5

3

1

COLDER

(Larger Numbers)

0 1 3 5 7 9 11 13 15

HOTTER

(Smaller Numbers)

0 1 3 5 7 9 11 13 15

1

5

4

3

2

9

13

12

11

2

4

CAUTION: Protect finish on SHOWER HEAD and
ARM when installing.

SHR.
ELBOW

TUB
NIPPLE

M968836 Rev.1.4

Thread DIVERTER KNOB (1) onto diverter stem.

PIPE

CAP

10

Hold ADAPTER (2) onto VALVE STEM (3) and install
ADAPTER SCREW (4) through ADAPTER (2) into
VALVE STEM (3).Tighten ADAPTER SCREW (4) to
secure ADAPTER (2) to VALVE STEM (3).
Install HANDLE BASE (5) onto ADAPTER (2). Insert
SET SCREW (6) into HANDLE BASE (5). Align
HANDLE BASE (4) and tighten with HEX WRENCH
(7) supplied.

1

3

7

Advertising