154

IP Module Firmware Upgrade Recovery

If a firmware upgrade procedure was interrupted due to a sudden power failure
or loss of network connection, the ordinary firmware upgrade recovery
procedures described in Firmware Upgrade Recovery, page 45, may not work
for the IP module. In that case, to recover the IP module, do the following:

1. Power off the KH1508i / KH1516i and remove its housing.

2. Using a jumper cap, short the jumper on the IP module (the daughter card

located at the rear-left of the unit, above the mainboard), labeled J2.

3. Power on the switch.

The IP module will now work with the factory default firmware.

4. Do the firmware upgrade procedure again.

5. After the upgrade procedure completes: power off the switch; remove the

jumper cap from J2; close the housing; and power the switch on again.