KH1508i / KH1516i User Manual

18

Hot Plugging

The KH1508i / KH1516i supports hot plugging – components can be removed
and added back into the installation by unplugging and replugging their cables
from their ports without the need to shut the unit down. In order for hot
plugging to work properly, however, the procedures described below must be
followed.

Hot Plugging Stations

You can switch station positions by simply unplugging from the old parent and
plugging into a new one. After you do, in order for the OSD menus to
correspond to the change, you must reset the OSD. See RESET STATION IDS,
page 29, for d
etails.

Hot Plugging KVM Ports

After switching KVM ports, in order for the OSD menus to correspond to the
change, you must manually reconfigure the OSD information for the new Port
information. See F3 SET, page 26, and the Port Setting selections under the F4
ADM
function, page 29, for details.

Note: If the computer’s Operating System doesn’t support hot plugging, this

function may not work properly.

Hot Plugging Console Ports:

Keyboard, monitor, and mouse can all be hot plugged. When hot plugging
the mouse:

Š You may unplug the mouse and plug it back in again (to reset the mouse,

for example), as long as you use the same mouse.

Š If you plug in a different mouse, all the stations and all the computers on

the installation must be shut down for 10 seconds, then restarted following
the Power Up Sequence described under Step 6 on page 16.)

Note: If, after hot plugging (or at any other time), there is no response to

keyboard and/or mouse input, perform a Keyboard and Mouse Reset
by pressing in the Reset switch (see page 7).