Adder Technology Adder TS4 User Manual

Page 12

Advertising
background image





























PC1

PC2

PC3

PC4

(PRIMARY)

0 to 00% of the left of PC goes to 0 to 00% of PC-Primary
0
to 00% of the bottom of PC goes to 0 to 00% of PC4

0 to 00% of the right of PC-Primary goes to 0 to 00% of PC
0
to 00% of the bottom of PC-Primary goes to 0 to 00% of PC3

0 to 00% of the top of PC3 goes to 0 to 00% of PC-Primary
0
to 00% of the right of PC3 goes to 0 to 00% of PC4

0 to 00% of the top of PC4 goes to 0 to 00% of PC
0
to 00% of the left of PC4 goes to 0 to 00% of PC3

PC1

PC2

PC3

PC4

(PRIMARY)

0 to 00% of the left of PC4 goes to 0 to 00% of PC3
0
to 00% of the right of PC4 goes to 0 to 00% of PC-Primary*

0 to 00% of the left of PC3 goes to 0 to 00% of PC
0
to 00% of the right of PC3 goes to 0 to 00% of PC4

0 to 00% of the left of PC-Primary goes to 0 to 00% of PC4*
0
to 00% of the right of PC-Primary goes to 0 to 00% of PC

0 to 00% of the left of PC goes to 0 to 00% of PC-Primary
0
to 00% of the right of PC goes to 0 to 00% of PC3

Set up examples for positional relationships

14 When all of the screen switching entries have been entered, click the OK

button to return to the main window. Now choose the Serial Port on the
primary computer to which the Adder TS4 serial cable is connected.

15 On each client system, select the ‘Use this computer as a client’ radio

button and enter the Screen Name (Hostname) of the primary system in the
‘Name of Server’ field.

Tip: To confirm that each client can see the server on the network, open

the Windows Command Prompt and enter: ping <server hostname>. If the
server can be seen, you will see replies to each outgoing message listed
within the Command Prompt window. This test can also be performed from
the server system to verify each of the clients.

16 On every system you now need to determine when Synchrony should start.

Depending on your access rights on each system, you can choose to launch
Synchrony either:

• When the system first starts up, or
• When you log in.
Click the ‘AutoStart...’ button to display the following dialog:

The application will check your current login status and present the

available choices to you.

*

Leave out these two

entries if you don’t need to
wrap around at each end

Screens arranged
in a square
formation

Screens
arranged
in a row

17 Click the relevant Install button and then click the Close button to return to

the main window.

You can now either click the Start button to begin each Synchrony session

immediately or wait until each system is next restarted. The taskbar on the
server system will begin greyed out

and will become coloured

once

the client systems are located.

In operation, as the mouse exceeds the boundary of one screen, the Adder

TS4 unit should switch across to the next system and screen.

Advertising