Air circulation and filters d, Warning, Caution – Amana PACKAGE HEAT PUMP User Manual

Page 5: Low voltage terminal strip, Low voltage connection heater kit control box, Low voltage connection unit control box, Lexible, Iring, Etup, Oltage

Advertising
background image

5

ON

ON

CG

Y

R

W

W

1
W2

O

Low Voltage

Terminal Strip

Low Voltage Connection

Heater Kit Control Box

Low Voltage

Terminal Strip

Low Voltage Connection

Unit Control Box

C

G

Y

R

W

W1

W2

O

1

2

3

4

5

6

7

8

9

1

3

L2

L1

4

5

THERMOSTAT

CB1

GY

BU

RD

0R

GY

BU

RD

BR

BR

BR

YL

YL

BK

VT

RD

VT

BR

BK

BK

RD

RD

BU

BK

BK

BK

BK

BK

BK

OL

OL

10KW

FIELD
CONNECTION
208/240 VAC
1

ø

USE COPPER
CONDUCTORS
ONLY-75°C MIN

RD

L2

L1

CB2

GND-75

SEQUENCER #1

RD

BK

GN

208/230 VAC 1

ø

T2

T1

TO CONTACTOR

Field Connection

Refer to the unit wiring diagram (see back of manual) for electrical
connections. When installed, the unit must be electrically grounded
in accordance with local codes or in the absence of local codes, with
the National Electrical Code, ANSI/NFPA No. 70, and/or the CSA
C22.1 Electrical Code, if an external source is utilized.

WARNING

T

O AVOID THE RISK OF ELECTRICAL SHOCK, WIRING TO THE UNIT MUST BE

POLARIZED AND GROUNDED.

CAUTION

T

O AVOID PROPERTY DAMAGE OR PERSONAL INJURY DUE TO FIRE, USE

ONLY COPPER CONDUCTORS.

CAUTION

T

O PREVENT IMPROPER AND DANGEROUS OPERATION DUE TO WIRING

ERRORS, LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING

CONTROLS.

V

ERIFY PROPER OPERATION AFTER SERVICING.

The best protection for the wiring is the lowest rated fuse or circuit
breaker which will supply power to the unit during normal operation
without nuisance trips. Such a device will provide maximum circuit
protection. DO NOT EXCEED THE MAXIMUM OVERCURRENT
DEVICE SIZE SHOWN ON UNIT DATA PLATE.
All line voltage connections must be made through weatherproof
fittings. All exterior power supply and ground wiring must be in ap-
proved weatherproof conduit. Low voltage wiring from the unit con-
trol panel to the thermostat requires coded cable.

F

LEXIBLE

W

IRING

S

ETUP

Line and low voltage wiring must enter the unit as shown.

ELECT.

CONTROL

BOX

EVAP

COIL

COMPRESSOR

LOW

VOLTAGE

REAR VIEW

SIDE VIEW

ELECTRICAL

SIDE VIEW

BLOWER

ELECTRICAL

SUPPLY

AIR

RETURN

AIR

HEATER

KIT

For knockout locations, see dimension drawing in the Product Data
Book applicable to your model* . Use the Single Point wiring kit to
add further flexibility to the installation wiring.

U

NIT

V

OLTAGE

The unit transformer is factory connected for 230V operation. If the
unit is to operate on 208V, reconnect the transformer primary lead
as shown on the unit wiring diagram.

AIR CIRCULATION AND FILTERS

D

OWNSHOT

A

IRFLOW

C

ONVERSION

Units are shipped from the factory ready for horizontal airflow. These
units can be easily converted from horizontal to downshot airflow
delivery. If conversion to vertical airflow is necessary, proceed as
follows:
Blower Rotation

1. Cut insulation around bottom openings and remove panels

from the bottom of the unit, saving the screws holding the
panels in place.

2. From the rear of the unit, remove the four (4) screws securing

the blower assembly in place and loosen the two (2) screws
directly below the duct opening.

*NOTE: Please contact your distributor or our website for the applicable product data book referred to in this manual.