Answer, A) normal message, B) error message – Sony PFM-42X1 User Manual

Page 23

Advertising
background image

1-19

PFM-42X1/42X1N

7. Answer
(a) Normal message
Answer

Header

0x70

Normal answer header

Category

0xXX

Code table (7-a) : Normal code

Code table (7-a)

Normal code

0x00

Completed

0x01

Limit over

0x02

Limit under

0x03

Command cancelled

0x04

Command all enable

0x05

Fail

Normal response.

The packet was received normally, but the data value was over the upper
limit.
Forcedly the monitor adjusted the data to maximum value.

The packet was received normally, but the data value was under the lower
limit.
Forcedly the monitor adjusted the data to minimum value.

The packet was received normally, but the command was cancelled because
the function was not in adjustable mode, such as a function displayed as “—
—” in user menu.

The packet was received normally.
The command function is all enable.

The packet was received normally, but the command was cancelled .
Please retry.

(b) Error message
Answer

Header

0xE0

Error answer header

Category

0xXX

Code table (7-b) : Error code

Code table (7-b)

Normal code

0x00

No function error

0x02

Data number error

0x06

Mode error

0x07

Time out

Packet header,category or function codes do not exist in this protocol.

The data value in “Data num” area of received packet was different from the
function’s own data number.

The monitor is already in the service mode via remote commander
operation.
(The service mode through IR remote has priority over the serial remote
command. )

Packet communication are interrupted by some error, and did not return to
normal communication within 2 seconds.