Summary, Installation, 1) connecting wires and mounting thermostat

Advertising
background image

SUMMARY

OPTIONS SELECTION

At the back of the thermostat, there are three selection switches to set at
your preferences.

Temperature in °C or °F, time in 12 or 24 hours and Early Start function.

TO SET TIME AND DAY

Press on DAY, HOUR and MIN buttons to adjust time and day.

TO RECORD THE (COMFORT) SETPOINT TEMPERATURE

Select chosen setpoint temperature by using or button. Press on

button (2 to 3 seconds) until icon appears on display.

TO RECORD THE (ECONOMY) SETPOINT TEMPERATURE

Select chosen setpoint temperature by using or button.
Press on button (2 to 3 seconds) until icon appears on display .

TO RECORD THE (VACATION) SETPOINT TEMPERATURE

To program the Vacation temperature, select the desired degree using the

buttons and press on the and buttons simultaneously

until the icon is displayed (app. 3 seconds).

OPERATING MODES

To select an operating mode, use MODE button.

AUTO:

Runs the program. or shows temperature setting
and can override temporarily your programming up to the
next program.

MAN:

Maintains the selected temperature. or changes
the temperature setting.

MODEL TH110A-SP-P (120 V)

u

u

u

u

u

u

INSTALLATION

PARTS INCLUDED

- One (1) TH110A-SP-P (120 VAC) thermostat
- Two (2) 6-32 screws
- Four (4) solderless connectors (for copper wire)

TURN OFF POWER OF THE HEATING SYSTEM AT THE MAIN POWER
PANEL TO AVOID ELECTRICAL SHOCK.
Keep air vents of the thermostat
clean and free from obstructions.

NOTE : The "Problems and Solutions" section at the end of this user's guide will

help you to correct your problems during the installation.

This thermostat has been designed to operate with any installation
which has a RESISTIVE load not exceeding 2400 W (20 A) @ 120 VAC
such as electric baseboards, radiant ceilings and floors, electric con-
vectors, etc. It is not compatible with a low voltage controller used by
a central heating system.

Electricians or experienced technicians should install the thermostat.

This thermostat is designed to be used with a self-protected heating
system equipped with thermal cut off and circuit breaker.

1) Connecting wires and mounting thermostat

Connect the rear thermostat wires to the 120 V LINE and to the load using
solderless connectors for copper wires. See schematic diagram.

Push the excess wire back into the electrical box to prevent interference with the
thermostat. Secure the thermostat using two (2) 6-32 screws. Once the
thermostat is properly installed, return power to heating system.

NOTE : All cables and connections must conform to the local electrical code.

WARNING: Special CO/ALR solderless connectors must be used when
connecting with aluminum conductors.

LOAD

120 V LINE

120 VAC

60 HZ

B

B

W

B

W

W

W

B

OLD

THERMOSTAT

LOAD

SUPPLY

BLACK

BLACK

BLACK

WHITE

BLACK

AFTER

BEFORE

Power-up

Set the On/Stand by switch to On.

When power is applied for the first time, the

display must show the time 00:00, the room

temperature and the Manual mode icon ( ).

Other information might show up on the display if

installation is defective or does not comply with the

instructions.

NOTE : The On/Stand by switch set to Stand by

will place the thermostat in sleep mode.

Ideal for summertime.

2400 W (NI) @ 120 Vca

920-110-001-00-1-B 1/3