Continuity diagram, Ontinuity, Iagram – Ariens Sno-Thro 926300 - 11526DLE User Manual

Page 34

Advertising
background image

34

C

ONTINUITY

D

IAGRAM

Model 926307, 308, 500, 501

PS0841

The diagrams below show the various states of connection for electrical components.
The solid lines on switchs show continuity.
NOTE: All switches are viewed from the rear.

S

A

M

B

R

G

S

A

M

B

R

G

S

A

M

B

R

G

OFF

RUN

START

HAND WARMER

OFF

HAND WARMER

ON

NOT ENERGIZED

ENERGIZED

Key Switch

(02739600)

Hand Warmer Switch
(02485700)

Solenoid (Top View)
(03679000)