23

Symptom Cause/Remedy

When I format the Memory Stick

MS Autorun deletes the data copied by the auto-run

media with an auto-run setting function when removing the Memory Stick media.
through the MS Gate application,

You may see this happening when you perform the

the display automatically returns

following procedure:

to the Home screen display.

1

Insert the Memory Stick media to start an
application automatically.

2

Start MS Gate without removing the Memory
Stick media.

3

Format the Memory Stick media.

When your unit registers that the Memory Stick
media is removed and that formatting is completed,
the Home screen is displayed and the auto-run
data is deleted from your CLIE handheld.

When tapping Tools under the

The Recover and Delete autorun setting buttons are

Options menu, the buttons are not

displayed in the Tools dialog box only if these

displayed in the Tools dialog box.

functions are available.
Recover: displays when the auto-run is performed
and MS Autorun is started without removing the
Memory Stick media.
Delete autorun setting: displays when an auto-run
setting file is stored in the inserted Memory Stick
media.

An error message appears notifying

the user that the CLIE internal

memory is getting low.

To run MS Autorun, more than 50KB free memory is
required.
To automatically start an application with
MS Autorun, free space in the amount equliry the
data size of the application to be installed is required.
Be sure to reserve enough free memory.