ADTRAN 1442880G1 User Manual

Page 2

Advertising
background image

The ADTRAN system chassis frame ground

terminal must be connected to a reliable earth

ground to ensure that the metal enclosure of the

SFP is properly grounded via the backplane

connector.

NOTE: The 3.125 Gigabit Ethernet port(s) are optical and

therefore are not classified as any type of port as

defined in Appendix B of GR-1089-CORE Issue 4.

The SFP is designed to meet the following environmental

classes:

ETSI EN 300 019-1-1 “Classification of

environmental conditions; Storage,” Class 1.2

ETSI EN 300 019-1-2 “Classification of

environmental conditions, Transportation,” Class 2.3

ETSI EN 300 019-1-3 “Classification of

environmental conditions, Stationary use at weather-

protected locations,” Class 3.3

The equipment is designed to function without degra-

dation during exposure to all test severities per Class 3.3.

COMPLIANCE

CAUTION: Electrostatic Discharge (ESD) can damage

electronic modules. When handling modules,

wear an antistatic discharge wrist strap to

prevent damage to electronic components. Place

modules in antistatic packing material when

transporting or storing. When working on

modules, always place them on an approved

antistatic mat that is electrically grounded.

The SFP is a Class 1 Laser Product and complies

with the Laser Safety requirements of FDA

21CFR 1040.10 and 1040.11, and EN60825-1

and -2. The SFP is NRTL Listed and CB Certified

to all applicable American and European safety

standards.

The SFP meets or exceeds all the applicable

requirements of NEBS, Telcordia GR-63-CORE,

and GR-1089-CORE. The SFP is intended for

deployment in Central Office type facilities,

EEEs, EECs, and locations where the NEC

applies (for example, Customer Premises). The

SFP is to be installed in ADTRAN products in

Restricted Access Locations only, and installed

by trained service personnel.

This device complies with Part 15 of the FCC rules.

Operation is subject to the following two conditions:

1. This device may not cause harmful interference
2. This device must accept any interference received,

including interference that may cause undesired

operation.

Changes or modifications not expressly approved by

ADTRAN could void the user's authority to operate this

equipment.

CAUTION: Per GR-1089-CORE the ADTRAN system that

the SFP is being deployed in is designed and

intended for installation as part of a Common

Bonding Network (CBN). The ADTRAN system

that the SFP is being deployed in is not designed

nor intended for installation as part of an

Isolated Bonding Network (IBN).
Per GR-1089-CORE Section 9, the SFP does not

have an internal DC connection between battery

return and frame ground. The SFP can be

installed in a DC-I (isolated) or DC-C (common)

installation. For installations where other cards

or the host system have internal connections

between battery return and frame ground, the

system would be intended for deployment only

in a DC-C installation.

Warranty

: ADTRAN will replace or repair this product within the warranty period if it does not meet

its published specifications or fails while in service. Warranty information can be found

online at

www.adtran.com/warranty

.

© 2008 ADTRAN, Inc. All Rights Reserved.

*61442880G1-22A*

C A U T I O N !

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

CLEI: SOOTAKEJ_ _
Product P/N: 1442880G1

Issue Date: 0804

Document P/N: 61442880G1-22A

PRICING AND AVAILABILITY

800.827.0807

TECHNICAL SUPPORT

800.726.8663

RETURN FOR REPAIR

256.963.8722

Small Form-Factor Pluggable

3.125 Gigabit Ethernet 80 km