American Standard 1340.225 User Manual

Installation instructions metering, Center set faucets

Advertising
background image

Connect water supply to FAUCET (1) with 1/2" IPS FLEXIBLE
SUPPLIES (1) or 3/8" O.D. BULL-NOSE RISERS (2).

Use adjustable wrench to tighten connections. Do not over
tighten. Be careful not to kink copper supply when bending.
Use tubing cutter to cut to proper length.

MAKE WATER SUPPLY CONNECTIONS

M968493

Plumbers' Putty or Caulking

Adjustable Wrench

Channel Locks

TOOLS REQUIRED



INSTALL FAUCET

1340.225
1340.255
1340.265

Certified to comply with ANSI A112.18.1

Thank you for selecting American-Standard...the
benchmark of fine quality for over 100 years.

To ensure that your installation proceeds
smoothly--please read these instructions carefully
before you begin.

Installation

Instructions

METERING

Center Set Faucets

FERRULE

COUPLING NUT

2

3

4

5

1

1

2

NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS MUST BE
PURCHASED SEPARATELY.

Insert faucet SHANKS through holes of SINK or
MOUNTING SURFACE.
Install GASKET (2), FRICTION WASHER (3), DEEP
WASHER (4) and LOCK NUT (5). onto SHANKS (6).

Tighten LOCK NUTS (5) firmly to secure FAUCET (1).

Apply a bead of PUTTY along the edge of the
underside of the FAUCET (1).

SINK OR
MOUNTING
SURFACE

PUTTY

SHANK

Turn off hot and cold water supplies before beginning.

CAUTION

1340.225

1340.255

1340.265

2.5mm Hex Wrench

Tubing Cutter

Advertising