Aiphone DUAL MASTER CHIMECOM SYSTEM C-123LW User Manual

Page 3

Advertising
background image

C-D

1

E

+

-

L
L

C-ML/A

RY-AC

+

-

12V DC

power supply

Component

Module

*

BELL

Power source

for bell

WHITE

RED

BLACK

YELLOW

YELLOW

1

E

Normally Open Dry

Contact to door

strike and power

WIRING DIAGRAM: C-123L/A System with External Signaling using RY-AC Relay

MODIFICATION INSTRUCTIONS:
C-ML/A with Door Release contact Modified to Normally Closed (for Magnetic Lock)

Magnetic locks require Normally
Closed contacts, keeping power
applied to the magnet to keep the
door locked, and breaking power to
release the door. These instructions
explain how to change the contact in
the C-ML/A to Normally Closed.

1. Remove back chassis of C-ML/A

and move PC-754 aside. Black
door release switch will be visible.

2. On the switch, move* the wire from

the NO contact (middle position) to
the NC contact (top position).
*Desoldering and resoldering is
required.

3. This modification will change the

door release button's function to
Normally Closed, to be used with a
magnetic lock device.

4. Switch contact rating is 1A at 50V

AC.

C-123LW Supplement

Pg. 3

Output of RY-AC (Yellow
wires) provide a momentary
dry contact closure while
the call button on the door
station is being pressed.

Component Module*
If a DAK-2S is not available, install components as shown below.
Capacitor: 25V, 15-33mfd Non-polarized (Aiphone NP-25V)
Diode: 1N 4148

To 1 of C-ML/A

To 1 of C-D and
WHITE wire of RY-AC

NOTE:Negatives of
power supplies must
be tied together.

C-ML/A Rear View with PC board removed.

+

-

60
H-2A

8

TH
A1

547

Door release

switch

COM

NO

NC

+

-

SKK-620

Advertising