ADTRAN MX2810 User Manual

Power supply unit, Mx2810

Advertising
background image

DESCRIPTION

The MX2810 Power Supply Unit (PSU) is a plug-in unit

for the MX2810 chassis that provides the necessary

voltages required to operate the MX2810. With two cards

installed, the MX2810 can recover from power supply

unit or power source failure, depending on configu-

ration. There are three possible configurations and

modes of operation.

The Non-Redundant Power Mode

This mode offers no backup protection, but only requires

one source of power and one PSU.

Power Supply Recovery Mode

This mode offers backup protection in the event of power

supply card failure. This configuration uses a primary

and a backup PSU, but only utilizes one source of power.

In this mode, the MX2810 can continue operation in the

event of a power supply unit failure, without inter-

rupting service.

Power Supply and Source Recovery Mode

This mode offers a backup system for both card and

source failure. In this mode, two power supply units are

installed and are connected to two individual power

sources. This allows the MX2810 to handle any combi-

nation of power source or power supply failure. The

MX2810 is able to internally re-route the power source if

a power supply card and the opposite power source fail.

Features

The PSU has the following features:

Receives unregulated power input

Faceplate status LEDs

Provision free plug-and-play

Hot-swappable

Meets the requirements for NEBS Level 3

MX2810

Power Supply Unit

CLEI: M3PQ0BHB_ _
Product P/N: 1185003L1

Issue Date: 0604

Document Number: 61185003L1-22B

TURN UP STEPS

1. Unpack the MX2810 Power Supply Unit and inspect for

damage. If damage is apparent, refer to your carrier or

supplier for remedy.

NOTE: To prevent ESD events when handling this equipment, all

personnel should utilize ESD shoes or wrist straps, or an
ESD flooring must be present.

2. Insert MX2810 PSU into one of the PSU slots. To insert,

hold the unit by the faceplate while supporting the

sides. Align the card edges to the guide grooves in the

designated PSU slot. Insert into chassis until the edge

connector seats firmly into the backplane. Lock the unit

in place by pushing in on the locking lever.

3. Verify that

PWR

(power) LED is active.

LED DESCRIPTIONS

The MX2810 PSU has LED status indicators. The LEDs

provided are

PWR

(power) and

CHK

(check). The power LED is

active when the unit is on and receiving full power. The

check LED is active when the power supply is failing or is

providing low power and needs to be checked.

COMPLIANCE

This product is intended for installation in a Restricted

Access location.

This device complies with part 15 of the FCC rules.

Operation is subject to the following two conditions:

1. This device may not cause harmful interference.
2. This device must accept any interference received,

including interference that may cause undesired

operation.

Changes or modifications not expressly approved by

ADTRAN could void the user’s authority to operate this

equipment.

Code

Input

Output

Power Code (PC)

F

C

Telecommunication Code (TC)

Installation Code (IC)

A

Warranty

: ADTRAN will replace or repair this product within the warranty period if it does not meet its

published specifications or fails while in service. Warranty information can be found online
at

www.adtran.com/warranty

.

©2006 ADTRAN, Inc. All Rights Reserved.