Multitasker – Altinex Computer/Component Video+ Audio Dual Twisted Pair Transmitter MT115-110 User Manual

Page 12

Advertising
background image

MULTITASKER

400-0433-003

11

6. [STA1]

This command enables automatic feedback
from the front panel. The command affects any
card with auto-feedback capability, not just the
MT115-110. The default at power on or reset is
STA0, off. For more details, see the [?Cn]
command definition.

Command Format: [STA1]

Feedback Prefix Definitions:
MT

Card model number

VR

Firmware revision

GN

Gain levels

EQ

Equalization value

Example 1:

Command = [GAIN1=10C3]
Feedback = (GN1004C03)

GN

= Gain

1004 = Levels (IN1=10, IN2= 04)
C04 = Card/Slot number

7. [STA0]

This command disables automatic feedback
from the card and front panel. The command
affects any card with auto-feedback capability,
not just the MT115-110 card.

The default at

power on or reset is STA0, OFF.

Command Format: [STA0]

8. [CLR]

This command clears the card settings and
returns it to the factory default values. The
default gain settings are 4 and the default
equalization settings are 32 for each input.

Command Format: [CLRCn]

Cn = Card ID (n = slot # from 1 to max slots)

Example:

In order to clear the card in slot 3, send the
command [CLRC3]. The card will respond with
the following feedback when complete:

FACTORY RESET COMPLETED

9. [TEST]

This command performs a series of tests on the
internal memory and displays a pass message if
successful. Otherwise, failures are indicated.

Command Format: [TESTCn]

Cn = Card ID (n = slot # from 1 to max slots)

Upon completion, the system will display the
results. This feedback will be similar to the
following:

MEMORY IC TEST RESULTS:
MEMORY IC PASS

10. [EQ]

This command displays the equalization setting
for an input and selects that input for adjustment
using the [+] and [-] commands.

Command Format: [EQmCn]

m

= Input # (m = 1 or 2)

Cn = Card ID (n = slot # from 1 to max slots)

Example:

Display the equalization setting for Input 1 of C3,
then increase the equalization level by 3 from a
starting value of 12.

Send the command [EQ1C3] and the current
setting for Input 1 will be displayed.

[12]

Next, send the commands [+], [+], and [+] to
increase the setting by 3. Send the [EQ]
command again to receive new value.

[15]

11. [EQ=]

This command sets the equalization for an input
to a value specified by the user.

Command Format: [EQm=xCn]

m

= Input # (m = 1 or 2)

x

= Equalization level (x = # from 1 to 64)

Cn = Card ID (n = slot # from 1 to max slots)

Advertising