Multi air conditioner system – Panasonic CU3E18LBE User Manual

Page 4

Advertising
background image

4

MULTI AIR CONDITIONER SYSTEM

DEFINITION

Multi air conditioner systems save space by letting you connect multiple indoor units to a single outdoor unit.

OPERATION CONDITION

OPERATION CONDITION

Multi Split Outdoor Unit

(CU-2E15LBE, CU-2E18LBE, CU-3E18LBE, CU-4E23LBE, CU-4E27CBPG)

Temperature (°C)

Indoor

Outdoor

Outdoor

CU-2E15LBE, CU-2E18LBE,

CU-4E27CBPG

CU-3E18LBE, CU-4E23LBE

*DBT *WBT

*DBT

*WBT

*DBT

*WBT

COOLING

Max.

32

23

43

26

46

26

Min.

16

11

16

11

-10

-

HEATING

Max.

30

-

24

18

24

18

Min.

16

-

-10

-11

-15

-16

* DBT: Dry bulb temperature

* WBT: Wet bulb temperature

Room A

Room A

Living room

Living room

Outdoor Unit

Outdoor Unit

INDOOR UNIT

INDOOR UNIT

• It is possible to operate the indoor units individually or simultaneously. The operation mode priority is given to the

fi rst unit that turned on.

• During operation, heating and cooling mode could not be activated at the same time for different indoor unit.

The power indicator blinks to indicate the indoor unit is standing by for different operation mode.