Product specification – Panasonic CSRE12HKE User Manual

Page 56

Advertising
background image




Indoor Unit
Outdoor Unit

Test conditions

1. Cooling: Indoor Dry Bulb Temp. (°C) 27

Outdoor Dry Bulb Temp. (°C) 35

Wet Bulb Temp. (°C) 19

Wet Bulb Temp. (°C) 24

Heating: Indoor Dry Bulb Temp. (°C) 20

Outdoor Dry Bulb Temp. (°C) 7

Wet Bulb Temp. (°C) 12 (MAX)

Wet Bulb Temp. (°C) 6

2. Standard piping length: 7.5m (Includes Indoor Unit piping length).

Model


CS-RE9HKE

CU-RE9HKE


CS-RE12HKE

CU-RE12HKE

COOL

HEAT

COOL

HEAT

Single, 230V, 50Hz

Single, 230V, 50Hz

Power/Current

[W]

730

820

1010

1120

[A]

3.50

3.90

4.70

5.00

Refrigerant

[kg]

R410A

0.78

R410A

0.97

Cooling Capacity

[kW]

2.60

3.50

Heating Capacity

[kW]

3.30

4.25

Noise Level

JIS C 9612

[<70 dB(A)]

[dB(A)]

42

42

42

42

Conditions

1m Distance

Max. cooling/

heating

operation

47

48

48

50

Sound power

level

[dB(A)]

53

53

53

53

60

61

61

63

Air Circulation

[m

3

/min.]

11.6

12.2

11.7

12.4

Product Weight

[kg]

8.5

8.5

28

30

Dimensions (H × W × D)

[mm]

280 Ч 799 Ч 183

280 Ч 799 Ч 183

540 Ч 780 Ч 289

540 Ч 780 Ч 289

kg

PRODUCT SPECIfICATION

PRODUCT SPECIfICATION

F566128-EN1.indd 56

2008-4-2 11:42:30

Advertising