Alliance Laundry Systems Washer-Extractor User Manual

Page 22

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Installation/Operation Supplement

F232145 (EN)

20

Electrical Specifications

35 Pound Capacity Models

Voltage Designation

Standard

Electric Heat

Code

Vo
lt

a

g

e

Cyc

le

Phase

Wire

Fu
ll Lo

ad

Amps

Cir
c

uit

Brea

ker

AW

G

mm

2

Full Lo

ad

Amps

Cir
c

uit

Brea

ker

AW

G

mm

2

2 Speed Models

C

380 – 415

50

3

4

5

15

14

2.5

26

30

10

6

D

220 – 240

50

3

3

7

20

12

4

43

50

6

16

F

440 – 480

60

3

3

5

15

14

2.5

26

30

10

6

O

200 – 240

60

3

3

7

20

12

4

43

50

6

16

Y

208 – 240

60

1

2

12

25

10

6

N/A

Variable-Speed Models

N

440 – 480

50/60

3

3

2.3

15

14

2.5

27.3

30

10

6

P

380 – 415

50/60

3

3

2.3

15

14

2.5

24

25

10

6

Q

208 – 240

50/60

3

3

5.9

15

14

2.5

43.4

45

6

16

T

200 – 240

50/60

1

2

5.9

15

14

2.5

N/A

X

200 – 240

50/60

1 or 3 2 or 3 5.9/5.9

15

14

2x2.5
3x2.5

N/A

NOTE: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.

Table 9

Electrical Specifications

40 Pound Capacity Models

Voltage Designation

Standard

Electric Heat

Code

Vo
lt

a

g

e

Cyc

le

Phase

Wire

Fu
ll Lo

ad

Amps

Cir
c

uit

Brea

ker

AW

G

mm

2

Full Loa

d

Amps

Cir
c

uit

Brea

ker

AW

G

mm

2

2 Speed Models

C

380 – 415

50

3

4

5

15

14

2.5

26

30

10

6

D

220 – 240

50

3

3

7

20

12

4

45

50

6

16

F

440 – 480

60

3

3

5

15

14

2.5

29

30

10

6

H

380

60

3

3

3

15

14

2.5

25

30

10

6

J

200

50

3

3

7

20

12

4

38

40

6

16

O

208 – 240

60

3

3

7

20

12

4

45

50

6

16

Y

208 – 240

60

1

2

13.5

30

10

6

N/A

Variable-Speed Models

N

440 – 480

50/60

3

3

6

15

14

2.5

30

30

10

6

P

380 – 415

50/60

3

3

6

15

14

2.5

29

30

10

6

Q

200 – 240

50/60

3

3

5

15

14

2.5

48

60

6

16

X

200 – 240

50/60

1 or 3 2 or 3

11/11

15

14

2.5

N/A

NOTE: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.