Troubleshooting – Aprilaire 8353 User Manual

Page 10

Advertising
background image

Troubleshooting

Symptom

Remedy

Thermostat does not turn

Check Wiring

on system

(see INSTALLATION).
Check fuse. Replace with 2 amp
Slo-Blo fuse if fuse has opened.

Thermostat turns on and off too

Increase Temperature Differential

frequently.

(see PROGRAMMING).

Display is blank, flashing or

Replace batteries.

constant “LO BAT.”

Weekend Program follows four

Verify that day of week is set

adjustment settings.

correctly (see PROGRAMMING).

System fan does not operate

Move fan option switch to either

properly.

gas or electric, to match system
(see INSTALLATION).

Time shown on display is not the

Change time of day setting

current time of day.

(see PROGRAMMING).

Thermostat does not

Thermostat in MANUAL mode

follow program.

(see PROGRAMMING).

Thermostat may not have been
programmed in HEAT or COOL
position. Verify program.

Check AM/PM indicators at time
of day and programmed time
changes (see PROGRAMMING).

Verify program and day of week
is correct (see PROGRAMMING).

If problems with thermostat cannot be solved, call:

Technical Support: 608-257-8801

Monday-Friday 7:45 am - 5:00 pm CST

10