Programming timer during startup, Programming timer during interval (fi) mode, Uf series water filtration system – Antunes, AJ UF-420/440 User Manual

Page 12: Operation (continued)

Advertising
background image

UF SERIES WATER FILTRATION SYSTEM

12

P/N 1010827 Rev. D 04/06

OPERATION (continued)

Programming Timer During Startup

NOTE: Once the UF unit is powered up, the

LED display cycles through the default or current

settings: Flush Duration (Fd) and its setting will

be followed by Flush Interval (Fi) and its settings.

At any time during this sequence (which lasts

approximately 30 seconds) the UF unit can be pro-

grammed.

SETTING THE FLUSH INTERVAL (FI)

1. When Fi (Figure 5) is displayed, press and

release the Start button to view the current set-

ting.

2. To make a program change, press and hold the

Start button to scroll through settings - release

the Start button at the desired setting (Figure 5).

3. If, after ten seconds, the Start button is not

pressed, the unit automatically returns to the

Flush Interval Mode.

NOTE: Flush Interval times are displayed in ten

minute intervals. After fifty minutes, Flush Interval

times are displayed in hours (Table A).

START

START

START

START

Figure 8. LED Display for Flush Duration Mode

Figure 9. Time Setting Fd Mode (55 Seconds)

Table A. LED Display Settings

Figure 7. Time Setting Fi Mode (22 Hours)

Figure 6. LED Display for Flush Interval Mode

SETTING FLUSH DURATION (FD)

2. When Fd is displayed, press and release the

Start button to view the current setting (Figure 8).

3. To make a program change, press and hold the

Start button to scroll through settings - release

the Start button at the desired setting (Figure 9).

4. After ten seconds, unless button is depressed,

unit automatically returns to Flush Interval Mode.

NOTE:

Fd

times are displayed in 5 second intervals

up to 60 seconds (Table A).

Programming Timer During Interval (FI)

Mode

TO SET FI - FLUSH INTERVAL MODE

NOTE: After power-up and cycling - Fi time setting

displays a flashing decimal point.

1. Press and hold down start button for four

seconds. Release button, LED will display Fd

followed by its setting.

2. When Fi (Figure 10) is displayed, press and release

button to view current setting.

3. To make a change, press and hold down the start

Fi - Flush Interval

Mode

Fd - Flush Duration

Mode

1- (10 minutes)

5 (5 seconds)

5- (50 Minutes )

10 (10 seconds)

01 (1 Hour)

15 (15 Seconds)

12 (12 Hours)

30 (30 Seconds)

24 (24 hours)

60 (60 Seconds)

Advertising