Panasonic FV-08WQ1 User Manual

Page 2

Advertising
background image

Wall

thickness

Exterior wall

Exterior
hood

Outdoor

Flexible
conduit

Wall sleeve

Junction box

Connector

Main unit

Indoor

2

Part name

Drawing

Screw

III

(4 x 8)

Template (Pattern paper)

Exterior hood

Externsion sleeve

Wall

thickness

Interior wall

Junction box

FV-08WQ1

Part name

Drawing

Wall sleeve

Screw

I

(4 x 30)

Mounting plate

Screw

II

(4 x 6) (for new

construction only)

List of components

Reference installation drawing

Description

This Panasonic wall mounted ventilating fan uses a propeller fan driven by a capacitor motor.
The motor is designed for extended service life with reduced energy consumption.
It also incorporates a thermal-cutoff device for safety. The grille is easily detachable from the main unit.

Interior wall

Wall thickness: 114.3 - 152.4 mm (4.5 - 6")
No extension sleeve is used.

Quantity

1

4

1

2

Quantity

1

1

1

1

Exterior wall

Exterior
hood

Outdoor

Flexible conduit

Wall sleeve

Connector

Main unit

Indoor

When the wall thickness is between 152.4 mm (6") and 254 mm (10"), mount the extension
sleeve as shown below. When the wall thickness is more than 254 mm (10"), prepare an
extension sleeve with an inner diameter of 207 mm (8 5/32") and a length of wall thickness
minus 127 mm (5"), and mount it as shown below. (The seam should be covered with
aluminum tape.)

Extension
sleeve