Alcatel-Lucent 1850 TSS-320 User Manual

Page 3

Advertising
background image

Alcatel-Lucent 1850 TSS-320 | Release 3 | Data Sheet

3

Protection

• Ethernet network protection

¬ RSTP: 802.1w
¬ MSTP: 802.1s
¬ Link aggregation

• T-MPLS network protection

¬ Tunnel Linear Protection 1:1

• SONET/SDH network protection

¬ Single- and dual-ended APS 1 + 1
¬ Subnetwork Connection protocol

(SnCp), unidirectional path-

switched ring (UPSR)

¬ Multiplex Section-protection Ring

(MSPRING) 2F bidirectional line

switching ring (BLSR)

• Equipment protection

¬ power protection
¬ Controller protection
¬ Universal switch protection

GMPLS control plane

• T-MPLS tunnel setup
• TDM HO path setup

Management

• Alcatel-Lucent 1350 Optical

Management System (oMS)

• TL1
• Zero-installation

craft (ZIC) terminal

• Simple Network Management

protocol (SnMp)

• Command line interface (CLI)
• Secure Shell (SSH) v2/Secure Socket

Layer (SSL) for secure connection

Physical specifications

ANSI

Dimensions: 1850 TSS-320 subrack

• Subrack dimensions

¬ Height: 624 mm (24.6 in.)
¬ Width: 532 mm (20.9 in.)
¬ Depth: 304.8 mm (12.0 in.)/

355.6 mm (14.0 in.)

• Designed to be installed in

a standard AnSi rack
¬ Height: 2.13 m (7 ft)
¬ Width: 660.4 mm (26.0 in.)
¬ Depth: 304.8 mm (12.0 in.)/

355.6 mm (14.0 in.)

Power and cooling

• Power supply: DC feed (-48 V DC

nominal)

• Power supply: -58 V
• Power consumption: up to 3500 W
• Cooling: forced air

Environmental

• Operating temperature:

-5°C to +45°C (23°F to 113°F)

• Relative humidity:

0% to 90%, non-condensed

Regulatory compliance

• CE and UL certification
• NEBS level 3
• FCC part 15 class A

ETSI

Dimensions: 1850 TSS-320 subrack

• Subrack dimensions

¬ Height: 624 mm (24.6 in.)
¬ Width: 532 mm (20.9 in.)
¬ Depth: 288 mm (11.3 in.)

• Designed to be installed in

a standard eTSi rack
¬ Height: 2.20 m (86.6 in.)
¬ Width: 600 mm (23.6 in.)
¬ Depth: 300 mm (11.8 in.)

Power and cooling

• Power supply: DC feed

(-48 v DC nominal)

• Power supply: -65 V
• Power consumption: up to 3500 W
• Cooling: forced air

Environment

• Operating temperature:

-5°C to +45°C (23°F to 113°F)

• Relative humidity: 0% to 90%,

non-condensed

Regulatory compliance

• CE certification
• Operating conditions:

eTS 300 019, Class 3.2

• Storage conditions:

eTS 300 019, Class 1.2

• Transportation conditions:

eTS 300 019, Class 2.2

• Electrostatic discharge (ESD)/

electromagnetic compatibility

(EMC): ETS 300 386 “Telecommuni-

cations Center”

Advertising