The EXT buttons provide an insert point in the control voltage signal, after the bias control but before
routing back to the channels.

During normal operation the control voltages generated by the sidechain are internally connected
to the CV Link switched for routing back to the channels. In EXT mode the control voltage is taken
from the rear connector instead of the sidechain outputs, allowing the unit to be slaved from a
second 8051 or 33609.

-

There is no EXT Control with 88R(S) console mounted compressors (AM5052 & AM5265).

Pin

Function

1

0V Reference

9

CV send, sidechain A

12

Remote power-on

5

CV send, sidechain B

13

CV return, sidechain B

14

CV return, sidechain A

15

24V Reference

Short to pin 12 to pin 1 to take the unit out of standby mode remotely.