Electrical work – Panasonic KYB64BX User Manual

Page 7

Advertising
background image

12

13

Electrical requirements

- This appliance must be supplied with the proper voltage and frequency, and

connected to an individual, properly earthed branch circuit, protected by a

circuit breaker or fuse. (The rating plate is on the bottom of the appliance.)

- This appliance is not fitted with other means for disconnection from

the supply mains having a contact separation in all poles that provide

full disconnection under overvoltage category III conditions. Means for

disconnection must be incorporated in the fixed wiring in accordance with

the wiring rules.

- You must use a two-wire, single-phase A.C. 220-240 V, 40 A, 50 Hz

electrical system. (It is also possible to use a four-wire, three-phase.)

If you connect to aluminum wiring, properly use connectors approved for

use with aluminum wiring.

- Check with the local utilities for electrical codes applied in the area.

Failure to wire the appliance according to governing codes may result in a

hazardous condition.

- After installation, show the customer where the breaker for the appliance is

located.

WARNING

Electrical work must be

performed by a legally

qualified electrician.

- In accordance with the electrical wiring rules, incorporate the earth leakage

circuit breaker in the home electrical wire.

- Follow the specification of the earth leakage circuit breaker as follows.

Rated current: 40 A, rated sensitivity current: 30 mA

Installation of the earth leakage circuit breaker

Electrical connections

1. Turn off power.

Turn off power at the circuit breaker or remove fuses to the appliance

branch circuit.

2. Connect the power cord.

Connect the power cord in accordance with all governing codes and

ordinances.

- Single-phase connection (220-240 V ~ 50 Hz)

Connect the wires in accordance with the instructions given in the

following table and diagram:

- Three-phase connection (380-415 V 2N~ 50 Hz)

Separate the L wires and connect them in accordance with the

instructions given in the following table and diagram:

Electirical cable

Wire connection

E: Yellow / Green

(Connect to the earth terminal)
N: Grey and Blue together

L: Black and Brown together

(Connect to the live terminal)

E
N

L

Electirical cable

Wire connection

E: Yellow / Green

(Connect to the earth terminal)
N: Grey and Blue together

L1: Black

L2: Brown

(Connect to the live terminal)

Electrical Work

L1
L2

E
N

English

Advertising