Aiphone SECURITY SUBSTATION AI-RS180 User Manual

Instruction manual

Advertising
background image

Please follow the instructions in this manual to obtain the optimum results from this unit.
We also recommend that you keep this manual handy for future reference.

AI-RS150
AI-RS160
AI-RS170
AI-RS180

SECURITY SUBSTATION

INSTRUCTION MANUAL

1. GENERAL DESCRIPTION

AIPHONE's AI-RS150, AI-RS160, AI-RS170, and AI-RS180 are Security Substations designed to be used with
AIPHONE's AI-900 Voice Security System.

2. CONNECTION

Connection to the AI-900RS (for 25 V line)

(AI-900RS)

A

B

C

Orange

Brown

Black

Speaker

Call button

Call lamp (AI-RS180 only)

Blue (HOT)

White (COM)

Open collector output
(AI-RS180 only)

AI-RS150/160/170/180

External
power supply

relay

diode

+24 VDC

GND

+

-

Blue (HOT)

White (COM)

AI-RS180

3. OPERATION

Pressing the call button calls the control station. The call lamp then flashes until the conversation begins, and
it remains lit during the conversation (AI-RS180 only). The open collector output is activated immediately after
pushing call buttons and remains active until call is cancelled (AI-RS180 only).

Note: AI-RS180 open collector output is 30 mA / 24 VDC (max.).

Connection to the external relay (AI-RS180 only)