Residential high efficiency gas, Distributed by, Flammable vapor ignition resistant water heaters – American Water Heater NRGSS01010 User Manual

Page 2

Advertising
background image

Order Entry and Sales
500 Princeton Road (FEDEX, UPS)
Johnson City, TN 37601-2030
P.O. Box 4808 (Mailing)
Johnson City, TN 37602-4808
(800) 937-1037
FAX (800) 581-7224

No part of this work may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, or by any information storage retrieval system, without permission in writing from American Water Heaters.

Distributed By:

Warranty and Service

500 Princeton Road (FEDEX, UPS)

Johnson City, TN 37601-2030

P.O. Box 1597 (Mailing)

Johnson City, TN 37605-1597

(800) 456-9805

FAX (800) 999-5210

B C

A

D

F

8”

GAS VALVE

DRAIN VALVE

HOT

CONNECTION

COLD

CONNECTION

ANODE ROD

ON/OFF SWITCH

FRONT VIEW

TOP VIEW

DRAFT HOOD

T&P VALVE

1/2”

E

Residential High Efficiency Gas

Residential gas water heater(s) shall be models ____________ as manufactured by American Water Heaters, or an approved equal, and shall have a ______ -year tank
warranty and a ______ -year parts warranty, when installed in a residential application. Heater(s) shall have a storage capacity of ______ gallons and shall have a rated
input of __________ BTUs, and shall be designed, tested and listed with CSA International in accordance with the latest edition of ANSI Z21.10.1 - CSA4.1 standard.
Heaters shall meet or exceed the Federal Energy Efficiency Standards effective January 20, 2004, according to the National Appliance Energy Conservation Act (NAECA) of
1992. The interior of the storage tank shall be lined with a Fused Ceramic Shield lining, fused to the tank at 1600° F, forming a corrosion-resistant lining; polymer linings
are not acceptable. Each tank shall be furnished with an internal powered anode for cathodic protection. The unit must be equipped with a combination gas control
thermostat and non-reset type ECO. A corrosion-resistant drain valve shall be provided on the front of each unit. The tank shall be totally encased in a steel jacket, painted
and insulated with a non-CFC foam to reduce standby heat loss. The tank must be design certified for 300 PSI test pressure and 150 working pressure.

Residential Gas High Efficiency Water Heater Specification

NRGSS01010

All dimension in inches.
Recovery capacity based on actual performance tests.
Water Connections – 3/4” on all models.
Not available in LP gas (Propane).
Certified for installations up to

00 ft. elevations.

Flammable Vapor Ignition Resistant Water Heaters

This FVIR design meets the American National Standards Institute standards (ANSI Z21.10.1 - 4.1 CSA Standards) that deal with the
accidental or unintended ignition of flammable vapors outside the water heater, such as those emitted by gasoline.

MODEL

NUMBER

GALLON

CAPACITY

ENERGY

FACTOR

BTU INPUT

PER HOUR

RECOVERY

AT 90°

RISE

FIRST

HOUR

RATING

FOAM

THICKNESS

(INCHES)

DIMENSIONS IN INCHES

DRAFT

HOOD

OUTLET

SHIPPING

WEIGHT

(LBS)

A

B

C

D

E

F

PCG6240T403NOV

40

.70

40,000

43

70 GPH

2

20

61-3/4

58

51-1/2

23-1/4

25

3 or 4

157

PCG6250T403NOV

50

.70

40,000

43

81 GPH

2

22

60-5/8

57-1/8

50-1/2

25-1/4

27

3 or 4

171

Maximum Hydrostatic Working Pressure: 150 PSI