OPERATING INSTRUCTIONS

Before using review all safety and connection directions before using charger. Failure to do so can damage battery and cause serious
injury or death.

Manual Chargers Models: 9006, 9010 and 9050

FEATURES:
All chargers come with a State of charge / Amp-meter
9006

SELECT SETTING switch with the following selections; OFF, 6A–12V, 2A–12V and 6A–6V

9010

SELECT SETTING switch with the following selections; OFF, 10A–12V, 2A–12V and 10A–6V

9050

SELECT SETTING switch with the following selections; 55A START, 10A–12V, 2A–12V and 10A–6V

CHARGE SETTING SWITCH USE:
55A START

Use this setting for starting a vehicle with a discharged battery.

6A and 10A–12V

Use this setting for charging large 12 volt batteries such as Automobiles, boats, etc.

2A–12V

Use this setting for charging small 12 volt batteries such as lawn tractor, motorcycles, etc.

6A and 10A–6V

Use this setting for charging 6 volt batteries, monitor battery continually, since this rating does not taper.

OFF

Use this setting when battery charging is completed.

Manual Charging: (12 volt only)
This method is for a standard LEAD-ACID battery in good condition at 70°F. Never charge a frozen battery.
Always terminate charge if battery temperature exceeds 120°F.
1.

Determine battery size (see chart below) round down.

2.

Determine battery state of discharge (see chart below) round down if possible.

3.

Connect charger to battery per instructions in sections 16, 17 and 18.

4.

Plug charger into wall outlet per instructions in section 19.

5.

Determine charge time (hrs) = Battery size x State of discharge x 1.2
Example: battery is 450Cca (56 AH) and 12.2V
Battery size is 4
State of discharge is .50
Time on Charge = 4 x .50 x 1.2 = 2.4 hrs

If the battery state of charge is unknown then monitor the charge current and when the current has dropped to 70% of the charger rating (for a
10A charger this would be 7A) charge for approximately 1 more hour.

For sealed batteries (valve regulated, AGM, Gel etc.) monitor the battery voltage and turn charger off when voltage reaches 14.0V. It is
important not to over-charge these batteries.

For Sulfated batteries ( this evident by a dead battery which when connected to the charger the charge current drops to 0 or a very low value)
leave battery on the charger monitoring the charge current, when the charge current starts to rise then charge as a normal battery. If the battery
is warm then lower the charge current to the lowest setting. Not all batteries can be rejuvenated.

BATTERY SIZE TABLE

BATTERY SIZE

3

4

5

6

7

8

9

10

11

Ampere Hours

34

50

63

75

87

100

113

125

140+

CA

330

490

600

725

850

970

1080

1180

1300

Cold Cranking Amps

275

400

500

600

700

800

900

1000

1100+

STATE OF CHARGE TABLE

STATE OF CHARGE

75%

50%

25%

DEAD

Specific Gravity

1.225

1.185

1.140

1.110

Open Circuit Voltage — 6V

6.2

6.05

5.95

5.9

Open Circuit Voltage — 12V

12.4

12.1

11.9

11.8

Automatic Chargers

Models: 9014, 9060, 9070 and 9090

Advertising