Airflow Direction Adjustment

Preparation Before Operation

Before operating the unit

2

3

Open the front panel.

Remove air filter.

Insert air purifying filter.
Insert the air filters.

Hold the tab to raise up
slightly and then pull down.

Hold the panel openers at both
sides and pull up the front panel.

Air
filter

Connect the power
supply cord to an
independent power
supply.

1

Air purifying
filter

Be careful not to
hurt your hands by
metal parts.

<Note>

Use under the following conditions :

(Unit in °C)

DBT : Dry Bulb Temperature

WBT : Wet Bulb Temperature

Maximum Temperature

Minimum Temperature

Cooling

Indoor

Outdoor

DBT

WBT

DBT

WBT

32

23

43

26

16

11

16

11

Heating

Indoor

Outdoor

DBT

WBT

DBT

WBT

30

24

18

16

-5

-6