VI. PERIODIC PREVENTIVE MAINTENANCE

NOTE: Periodic inspection and preventive maintenance of your total
heating system is important for efficient and safe operation. Your heating
dealer should perform humidifier service at the same time.

All models are equipped with an in-line water strainer and orifice as
shown below. These parts should be inspected and cleaned periodically to
assure continued proper unit performance.

1. Disconnect electrical power to the furnace

and shut off water supply.

2. Disconnect the water line at the inlet

compression nut.

3. Remove the in-line strainer from inside the

inlet fitting by using a small nail or wire.

4. Flush the in-line strainer clean or replace

with a new strainer, Service Part No.
SRA00859.

5. Replace the in-line strainer and reconnect

the inlet water line.
(Double Wrench To Prevent Leaking.)

6. Disconnect the water line at the outlet

compression nut.

7. Remove the orifice from the copper or plastic tube and make sure this

small opening is unplugged.

8. Replace the orifice and reconnect the outlet water line.

(Double Wrench To Prevent Leaking.)

9. Turn on water supply @ Saddle Valve and reconnect electrical power to

the furnace.